4-2 Basic Settings and Advanced Settings

4-26

4

Set
ting V

a

rious

F

unct

ions

IB-E

The hysteresis for the tolerance setting value is set.
If the judgment value (P.V.) fluctuates due to the vibration of the object, etc. and the
judgment output repeats ON/OFF, increasing the hysteresis value stabilizes ON/OFF.

"3-6 Setting the Tolerance Setting Value" (page 3-13)

" 1. Measurement Mode" (page 4-8)

8. Hysteresis

Item

Measurement mode

Setting range

Default value

Hysteresis

% mode

0.00 to 999.99

0.00

Dimension mode

0.000 to 99.999

0.000

Reference

The above is the timing chart when the output mode of judgment output is
Normally Open (default value). ON/OFF is reversed for Normally Closed.

" 4. Output Mode" (page 4-13)

Time

Hysteresis

Hysteresis

Judgment value (P.V.)

HIGH setting value

LOW setting value

ON

OFF

ON

OFF

ON

OFF

HIGH judgment output

GO judgment output

LOW judgment output