Safety information for ib series, General precautions, Safety precautions on laser products – KEYENCE IB Series User Manual
Page 3
1
IB-E
Safety Information for IB Series
*
The classification is implemented based on IEC60825-1 following the requirement of Laser Notice No.50 of
FDA (CDRH).
General Precautions
WARNING
• This product is just intended to detect object(s). Do not use this
product for the purpose of protecting a human body or a part of
human body.
• This product is not intended for use as explosion-proof product. Do
not use this product in a hazardous location and/or potentially
explosive atmosphere.
• Provide sufficient safety measures to prevent various damage in the
event this product fails.
NOTICE
• When using this product in combination with other devices, there
may be cases when the functions and performance cannot be
achieved because of the working conditions or environment, etc.
Always review the combination carefully before starting use.
• Do not apply sudden temperature changes on any device including the
peripheral devices. Condensation could cause device damage.
Safety Precautions on Laser Products
WARNING
• This product uses a semiconductor laser as a light source.
• Use of controls or adjustments or performance of procedures other
than those specified herein may result in hazardous radiation
exposure.
• Follow the instructions mentioned in this manual. Otherwise, injury
to the human body (eyes and skin) may result.
Precautions on Class 1 laser products
• Do not stare into the beam.
• Do not disassemble this product. Laser emission from this product
is not automatically stopped when it is disassembled.
Model
IB-01/IB-05/IB-10/IB-30
Wavelength
660 nm
Output
170
μW
Pulse width
30
μs
FDA (CDRH) Part 1040.10
*
Class 1 Laser Product
IEC60825-1
Class 1 Laser Product
Point
Laser emission stop input
When laser emission stop input is set as an external input, laser
emission can be stopped by turning on the external input (2 ms or
more). Laser emission stays stopped while the external input is on.
The laser is emitted within 3 ms after the external input is turned off.
96099E