Analog output accuracy, F'(.v, 2 basic settings and advanced settings – KEYENCE IB Series User Manual
Page 80: External input, Lower limit specifying screen, Measurement mode" (page 4-8), Voltage output current output output range, 1 mv, 5 μa accuracy in respect to display, 05% of f.s
4-2 Basic Settings and Advanced Settings
4-28
4
Set
ting V
a
rious
F
unct
ions
IB-E
The upper and lower limits for the different selections of analog outputs are as follows.
Upper limit setting screen and lower limit setting screen
When set to the default state [dEFLt], the following screens will be skipped.
When set to free range, the upper limit setting and lower limit setting screens will appear.
Press the / button on each setting screen to specify the upper limit and the lower limit.
" 1. Measurement Mode" (page 4-8)
Analog output accuracy
The analog output can be selected from ± 5 V, 1-5 V, 0-5 V or 4-20 mA.
*1
The averaging is as follows after 512 times.
512 times: Sampling rate x 2
1024 times: Sampling rate x 4
2048 times: Sampling rate x 8
4096 times: Sampling rate x 16
Analog setting
Output upper limit
Output lower limit
OFF
Not output
0-5v
5V
0V
-5-5v
5V
- 5V
1-5v
5V
1V
AMPR
20mA
4mA
Item
Measurement mode
Setting range
Default value
Upper limit
% mode
- 999.99 to 999.99
100.00
Dimension mode
- 99.999 to 99.999
10.000
Lower limit
% mode
- 999.99 to 999.99
0.00
Dimension mode
- 99.999 to 99.999
0.000
(TGG
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
#P)
GO
HOLD
CALC
CHECK
LASER
BANK
0
1
2
3
HI
GO
LO
R.V. ANALOG
HI SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
#P*
HOLD CALC CHECK
LASER
BANK
0
1
2
3
HI
GO
LO
R.V. ANALOG
HI SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
#P.
HOLD CALC CHECK
F'(.V
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
KP
GO
HOLD
CALC
CHECK
9. Analog output
scaling
Upper limit
specifying screen
[MODE]
or
[MODE]
or
10. External
input
[MODE]
or
Lower limit
specifying screen
Voltage output
Current output
Output range
±
5 V (Full scale 10 V)
4 - 20 mA (Full scale 16 mA)
Output resistance
100
Ω
—
Maximum load resistance
—
350
Ω
Repeatability
±
1 mV
±
1.5
μA
Accuracy in respect to display
±
0.05% of F.S.
±
0.25% of F.S.
Temperature characteristics
±
0.005% of F.S./±
°C
±
0.01% of F.S./
°C
Refresh rate
*1
Same as sensor head sampling rate
Response delay time
Same as response time (judgment output)
Time constant
10
μS (90% response)
30
μS (90% response)