3-6 Setting the Tolerance Setting Value
3-16
3
B
a
sic O
perat
io
ns
IB-E
2-point tuning
With this method, the median value of the good target and defective target is set as the
tolerance setting value when there are good target and HIGH/LOW defective target.
1
Press the / button several times on the main screen. Then display the
HIGH setting value on the sub display (lower level).
"Sub Display (Lower Level)" (page 3-4)
2
Measure the good target and press the [SET] button. (HIGH side 1st point
confirmation operation)
The internal measurement value (R.V.) is imported as a good target measurement
value.
[Hiset] is displayed on the main display (upper level).
3
Measure the HIGH side defective target and press the [SET] button. (HIGH
side 2nd point confirmation operation)
The internal measurement value (R.V.) is imported as a measurement value for
HIGH side defective target.
After [set] blinks on the main display (upper level), the judgment value (P.V.) is
displayed.
On the sub display (lower level), the median value of the good target value (1st point)
imported on step 5 and HIGH defective target value (2nd point) is displayed.
Setting the HIGH setting value (upper limit) is complete.
4
Press the button once and display the LOW setting value on the sub
display (lower level).
Point
2-point tuning cannot be performed if the internal measurement
value (R.V.) is [-----], [FFFF] or [-FFFF]. If performed, [no.uAL] will
blink several times on the main display.
GO
LASER
BANK
0
1
2
3
HI
LO
R.V. ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
HOLD
CALC
CHECK
[HI]
ON
HIGH setting value
GO
HOLD
CALC
CHECK
LASER
BANK
0
1
2
3
HI
LO
R.V. ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
LOW setting value
[LO]