2-1 Mounting and Wiring the Sensor Amplifier Unit

2-4

2

Inst
all

at

ion and

Connec

tion

IB-E

Panel mount type, main unit (IB-1500)

1

Make a hole on the panel as shown in the diagrams below.

2

Insert the back side of amplifier to the hole of the panel.

3

Arrange the panel mounting tool in the direction below, mount to the
amplifier from the back and attach the front protection cover to the
amplifier.

To remove the panel mounting tool, widen the claws at both ends of the panel
mounting tool using a screwdriver, as illustrated below.

When stacking the units vertically

When stacking the units horizontally

• Panel thicknes 1 to 6 mm
• X = 48 x (Number of amplifiers) - 3

45 mm

X mm

+ 0.6
- 0

Minimum 85 mm

45 mm

45 mm

+ 0.6

- 0

+ 0.6

- 0

Panel mounting

bracket

Panel

Amplifier

Front protection

cover