Connecting and Mounting the Sensor Head

Mounting

Mount the sensor head with the
enclosed screws (IB-01/IB-05/IB-10:
M3, IB-30: M4).
Tightening torque: 0.3 N·m or less
(Tightening torque for IB-01: 0.1 N·m
or less)

Mounting the Sensor Head

Point

• Always use mounting holes facing the same direction for the

sensor head transmitter and receiver. (Excluding IB-01)

• Do not tighten the screws with a torque exceeding 0.3 N·m. The

sensor head could deform, thus preventing beam axis alignment.

Important

When mounting the sensor, confirm that the transmitter and receiver
faces on which the nameplate label is attached are facing the same