2-1 Mounting and Wiring the Sensor Amplifier Unit

2-7

IB-E

2

Inst
all

at

ion and

Connec

tion

Power/Input-output cable

"Output Circuit" (page 5-4)

*1

IB-1050/IB-1550 (expansion units) do not have brown, blue or light blue wires. Power
is supplied to the expansion units through IB-1000/IB-1500 (main unit).

*2

The analog output can be set to any of the following options either “when the power is
turned on for the first time” or “when performing the initial reset”.
• Not used (OFF)
• 0 to 5 V
• -5 to 5 V
• 1 to 5 V
• 4 to 20 mA

"3-1 Operation when the Power is Turned On for the First Time" (page 3-2)
"3-5 Initial Reset (Initialize)" (page 3-12)

*3

The external input can be selected among the following in addition to the above.
• Bank A input
• Bank B input
• Laser emission stop input
• Not used (OFF)
Adjust input can be selected only for the external input 4.

"10. External Input" (page 4-29)

Brown

Blue

Black

White

Gray

Light blue

Orange

Shield

Pink

Yellow

Pink/Purple

Purple

Green

10 to 30 VDC

0 V

HIGH judgment output

LOW judgment output

GO judgment output

Analog output +

Analog output GND

External input 1 (Zero shift input)

External input 2 (Reset input)

External input 3 (Timing input)

External input 4 (Not used)

Check output

*1

*1

*1

*2

*2

*3

*3

*3

*3