Bottom hold – KEYENCE IB Series User Manual
Page 69
4-2 Basic Settings and Advanced Settings
4-17
IB-E
4
Set
ting V
a
rious
F
unct
ions
Bottom hold
The minimum value of the specified period (sampling period) is held as a judgment value
(P.V.).
When “Level” is set for " 6. Timing Input" (page 4-23)
The sampling period is from the falling edge of the timing input to the next rising edge. On
the rising edge, the internal measurement value (R.V.) minimum during the sampling period
is held as a judgment value. When the timing input is turned OFF, the next sampling period
begins.
*1
" 10. External Input" (page 4-29)
When “Edge” is set for " 6. Timing Input" (page 4-23)
The sampling period is from the rising edge of the timing input to the next rising edge of the
timing input. On the rising edge, the internal measurement value (R.V.) minimum during the
sampling period is held as a judgment value. When the timing input is turned ON, the next
sampling period has already begun.
*1
" 10. External Input" (page 4-29)
Display value
Time
Timing Input
Sampling period
Sampling period
Sampling period
ON
OFF
Power ON or
Reset input*
1
After the power is turned on or reset is input, the judgment value (P.V.) is
[- - - - -] until the timing input is first turned ON.
Judgment value (P.V.)
Internal measurement
value (R.V.)
Display value
Time
Timing Input
Sampling period
Sampling period
Sampling period
ON
OFF
Power ON or
Reset input*
1
After the power is turned on or reset is input, the judgment value (P.V.) is
[- - - - -] until the timing input is first turned ON.
Judgment value (P.V.)
Internal measurement
value (R.V.)