Initial Reset (Initialize)
When initial reset is performed, all settings, excluding the calibration function, are
initialized. (When initial reset is performed, make sure to register the reference light again.
"3-4 Reference Light Registration (Gain Adjustment) and Adjust Function" (page 3-10)
The polarity of the judgment output and check output, and also the analog output setting,
can be changed with the same operation.
Main screen
1
While holding down the [MODE] button on the main
screen, press the [SET] button 5 times.
[reset] will be displayed on the main display.
While pressing the
[MODE] button,
press the [SET]
button 5 times.
2
Press the / button to select [yes] and press the
[MODE] button.
If [no] is selected, the settings of output polarity and analog
output can be changed without initial reset.
[MODE] button
3
Press the / button to select the output polarity
and press the [MODE] button.
[MODE] button
4
Press the / button to select the analog output
and press the [MODE] button.
"9. Analog Output Scaling" (page 4-27)
[MODE] button
5
After the initialization is complete, [end] blinks several
times on the sub display and the main screen is
restored.
Reference
• When buttons other than the / and [MODE] buttons are pressed
during the initial reset procedure, the initial reset is canceled and the
screen in step 2 is restored.
• When you attempt to initialize the unit while the key lock
function is set, the screen shown on the right appears
and the initialization fails.
Cancel the key lock before attempting to initialize the
unit.
"3-9 Key Lock Function" (page 3-23)
LASER
BANK
0
1
2
3
HI
GO
LO
R.V. ANALOG
HI SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
HOLD CALC CHECK
;GU
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
T'5'V
GO
HOLD CALC CHECK
Performing the initial reset
PRP
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
QWV
GO
HOLD CALC CHECK
Output polarity
Setting value
Description
npn
NPN output
pnp
PNP output
QHH
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
#P.)
GO
HOLD CALC CHECK
Analog output
Setting value
Description
off
Not using the analog output
0-5u
Analog output range is from 0 to 5 V.
-5-5u
Analog output range is ±5 V.
1-5u
Analog output range is from 1 to 5 V.
aMpr
Analog output range is from 4 to 20 mA.
'PF
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
T'5'V
GO
HOLD
CALC
CHECK
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI
SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
.QE
GO
HOLD
CALC
CHECK