Analog output scaling, Analog output scaling -27 – KEYENCE IB Series User Manual

Page 79

background image

4-2 Basic Settings and Advanced Settings

4-27

IB-E

4

Set
ting V

a

rious

F

unct

ions

The analog output scaling for the judgment value (P.V.) is set.
If the setting not to output the analog output is set, this screen is skipped.

"3-1 Operation when the Power is Turned On for the First Time" (page 3-2)
"3-5 Initial Reset (Initialize)" (page 3-12)

Relation of voltage and analog output in default state (dEFLt)

• Analog output setting: Other than -5 to 5 V

• Analog output setting: -5 to 5 V

9. Analog Output Scaling

Analog output

Description

Default

value

No scaling
(Default setting)

Scaling is not performed.

Free range

Scaling is performed. The analog output range can be
changed by specifying the upper limit and lower limit of
the judgment value (P.V.).

Example 1: Lower limit < Upper limit

(Analog output 1 to 5 V)

Example 2: Lower limit > Upper limit

(Analog output 1 to 5 V)

Reference

If Upper limit = Lower limit is set, the analog output is output as below.
Judgment value (P.V.)

≤ Upper limit: Analog output lower limit (1 V when 1 to 5 V)

Judgment value (P.V.) > Upper limit: Analog output upper limit (5 V when 1
to 5 V)

5

1

V

Judgment
value
(P.V.)

Lower limit Upper limit

Output
lower limit

Output
upper limit

Judgment
value
(P.V.)

Lower limit Upper limit

V

5

1

Output
lower limit

Output
upper limit

% mode

Dimension mode

% mode

Dimension mode

Model

Upper limit

Lower limit

IB-01

100.00

0.00

IB-05

0.00

IB-10

0.00

IB-30

0.00

Model

Upper limit

Lower limit

IB-01

1.000

0.000

IB-05

5.000

0.000

IB-10

10.000

0.000

IB-30

30.000

0.000

Model

Upper limit

Lower limit

IB-01

100.00

- 100.00

IB-05
IB-10
IB-30

Model

Upper limit

Lower limit

IB-01

1.000

- 1.000

IB-05

5.000

- 5.000

IB-10

10.000

- 10.000

IB-30

30.000

- 30.000