Troubleshoot the 1769-aentr adapter – Rockwell Automation 1734-AENTR EtherNet/IP Network Configuration User Manual User Manual
Page 136
136
Rockwell Automation Publication ENET-UM001L-EN-P - March 2014
Chapter 10 Troubleshoot an EtherNet/IP Communication Module with Diagnostic Web Pages
136
Rockwell Automation Publication ENET-UM001L-EN-P - March 2014
Chapter 10 Troubleshoot an EtherNet/IP Communication Module with Diagnostic Web Pages
Troubleshoot the
1769-AENTR Adapter
Use this table to determine what diagnostic web page to use when you
troubleshoot issues on your module.
Table 34 - Required Diagnostic Web Pages
Technical Issue
Diagnostic Web Page
CPU utilization
Diagnostic Overview
CIP connection statistics
TCP connections
HMI/MSG statistics
I/O and produce/consume packets per second
I/O and produce/consume packet counts
Link status
Ethernet Statistics
Speed
Duplex
Autonegotiate status
Ethernet errors
Status of I/O connections
I/O Connections
Number of lost I/O connections
IMPORTANT
The 1769-AENTR communication module has two ports. Some diagnostics are
tracked for Port 1 and Port 2 because the values can be different between
ports.
- 1734-AENT EtherNet/IP Network Configuration User Manual 22-COMM-E EtherNet/IP Network Configuration User Manual 20-COMM-E EtherNet/IP Network Configuration User Manual 1794-AENT EtherNet/IP Network Configuration User Manual 1783-Etxx EtherNet/IP Network Configuration User Manual 1769-Lxxx EtherNet/IP Network Configuration User Manual 1756-Enxx EtherNet/IP Network Configuration User Manual