beautypg.com

Start-up – Rockwell Automation 8510 AC Spindle Drive System User Manual User Manual

Page 99

background image

9

Chapter

9-95

Start-Up

Chapter Objectives

The steps needed to start-up the 8510 AC Drive System are provided in
this chapter.

Conventions Used in this Manual

To help differentiate input/output names, programmable parameters and
programmable values, the following conventions will be used throughout
this chapter and the remainder of this manual.

Input and Output Names

will appear in Initial Capital Letters

Programming Display Text

will appear in italics

Menu Names

will appear with ALL CAPITALS

Parameter Names

will appear with Initial Capital Letters

Programmable Parameter Values

will appear in “quotes”

Start-Up Procedure

Since most start-up difficulties are the result of incorrect wiring, every
precaution must be taken to assure that the wiring is done as instructed. All
items must be read and thoroughly understood before the actual
wiring begins.

ATTENTION: Power must be applied to the system to perform
many of the adjustments specified in the following paragraphs.
Some of the voltages present are at incoming line potential. To
avoid injury to personnel and/or damage to equipment, only
qualified service personnel should perform the following
start-up procedure. Thoroughly read and understand the
following procedure before beginning. If an event does not
occur while performing this start-up, Do Not Proceed. Remove
Power
by opening the branch circuit disconnect device and
correct the malfunction before continuing.

ATTENTION: High voltage that presents an electrical shock
hazard is present on the Main Control Board of the
8510A-A11-x2 and 8510A-A22-x2 drives. The upper right half
of the board contains the IGBT gate drive circuits, while the
upper left quarter contains the power supply. DC bus voltage
(approximately 325V DC) is present in both of these areas.
These areas contain the voltage warning symbol (see example)
and are outlined with a heavy white line. To avoid injury, only
qualified personnel should perform start-up or maintenance
procedures on this drive.

!

!