Table 6.A
1327A Radial Load Capabilities

Motor

Maximum

Catalog Number

Radial Load

1

1327AC-AFM-02

133 kg (292 lb.)

1327AC-AFM-04

165 kg (364 lb.)

1327AC-AFM-06

167 kg (368 lb.)

1327AC-AFL-08

313 kg (688 lb.)

1327AC-AFL-11

335 kg (737 lb.)

1327AB-AFL-15

356 kg (784 lb.)

1327AB-AFL-19

373 kg (820 lb.)

1327AB-AFL-22

384 kg (844 lb.)

1327AD-ABL-04

300 kg (660 lb.)

1327AD-ABL-06

310 kg (682 lb.)

1327AD-ABL-08

360 kg (792 lb.)

1327AD-ACL-08

380 kg (836 lb.)

1327AD-AAK-11

580 kg (1276 lb.)

1327AD-AAK-15

600 kg (1320 lb.)

1327AD-AAK-19

610 kg (1342 lb.)

1

Load applied at dimension AH/3 or (N-W)/3 from the shaft

tip.

Wiring Considerations

Read through and understand the following points before wiring the 1327
motor.

– The terminal box includes two cable entry holes. One hole has a solid

cover plate and the other hole has a cover plate to accommodate either
IS0-228 “PF” type conduit fittings or ANSI “NPT” type conduit fittings.
On request, cover plates to accommodate DIN-40430 “PG” type conduit
fittings are available.

– Both motor power and motor feedback leads can be brought through the

same conduit. Carefully follow all grounding and shielding procedures
outlined in Chapter 8.

– The motor fan must be operating whenever the spindle motor is

operating. The motor will quickly overheat if it is operated with the fan
de-energized.