Rockwell Automation 8510 AC Spindle Drive System User Manual User Manual
Page 56
![background image](/manuals/580060/56/background.png)
Motor Installation
Chapter 6
6-52
Table 6.A
1327A Radial Load Capabilities
Motor
Maximum
Catalog Number
Radial Load
1
1327AC-AFM-02
133 kg (292 lb.)
1327AC-AFM-04
165 kg (364 lb.)
1327AC-AFM-06
167 kg (368 lb.)
1327AC-AFL-08
313 kg (688 lb.)
1327AC-AFL-11
335 kg (737 lb.)
1327AB-AFL-15
356 kg (784 lb.)
1327AB-AFL-19
373 kg (820 lb.)
1327AB-AFL-22
384 kg (844 lb.)
1327AD-ABL-04
300 kg (660 lb.)
1327AD-ABL-06
310 kg (682 lb.)
1327AD-ABL-08
360 kg (792 lb.)
1327AD-ACL-08
380 kg (836 lb.)
1327AD-AAK-11
580 kg (1276 lb.)
1327AD-AAK-15
600 kg (1320 lb.)
1327AD-AAK-19
610 kg (1342 lb.)
1
Load applied at dimension AH/3 or (N-W)/3 from the shaft
tip.
Wiring Considerations
Read through and understand the following points before wiring the 1327
motor.
– The terminal box includes two cable entry holes. One hole has a solid
cover plate and the other hole has a cover plate to accommodate either
IS0-228 “PF” type conduit fittings or ANSI “NPT” type conduit fittings.
On request, cover plates to accommodate DIN-40430 “PG” type conduit
fittings are available.
– Both motor power and motor feedback leads can be brought through the
same conduit. Carefully follow all grounding and shielding procedures
outlined in Chapter 8.
– The motor fan must be operating whenever the spindle motor is
operating. The motor will quickly overheat if it is operated with the fan
de-energized.