beautypg.com

Rockwell Automation 8510 AC Spindle Drive System User Manual User Manual

Page 112

background image

Display Panel & Fault Diagnostics

Chapter 10

10-108

Orient Error
When selected, indicates that the display is currently showing the value of
the position error when the drive is in spindle orient mode. This is a bipolar
output.

Data Format: DEG 00.000

DIAGNOSTICS

The information displayed on the diagnostic display can help to isolate a
malfunction in the drive. The following paragraphs describe the diagnostic
displays available. Refer to Chapter 11 for further troubleshooting
information.

I/O Inputs
This parameter indicates the status of all inputs. For ease in identifying
each input, successive letters of the alphabet are used to show when they
are On. When an input is Off, a dash (–) will be displayed. Refer to
Table 10.A for the input associated with each letter.

Data Format (line 1): I/O Inputs
Data Format (line 2): JKLMNOPQRSTUV

Table 10.A
I/O Inputs

Display Letter

Input Signal Name

J

Coast-to-Stop

K

Drive Reset

L

Drive Enable

M

Forward Run

N

Reverse Run

O

Low Torque Limit Select

P

Accel/Decel Rate Select

Q

Spindle/Servo Mode Select

R

Servo Input Scaling - High/Low

S

Gear Ratio Active Bit #2

T

Gear Ratio Active Bit #1

U

Orient Command

V

High Motor Winding Select Command