Specifications, Chapter – Rockwell Automation 8510 AC Spindle Drive System User Manual User Manual

Page 13

background image

2

Chapter

2-9

Specifications

Chapter Objectives

Chapter 2 provides the specifications for the 8510 AC Spindle Drive
System. Specifications have been grouped by type of motor.

Standard Single Speed 1327AC Motor & 8510 Drive

Motor

1327AC -

Output Power Rating

S1 - Continuous - kW (HP)
S2 - 30 Minute - kW (HP)

1

S6 - 60% Duty - kW (HP)

2

1 Minute Peak - kW (HP)

Rated Speed

Base RPM
Maximum RPM
Constant Power/Speed Range

Rated Torque

Continuous N-m (lb-ft)

Rated Current

30 Minute Output Amperes

Rotor Inertia

kg-m

2

(lb.-in.-s

2

)

Bearing Load

Max. Radial - kg (lb)

Motor Weight

kg (lbs.)

Electrical Design

Vibration

Audible Noise

Feedback Device

Rated Ambient Temperature

Possible Mounting Methods

AFM-02

2.2 (3)
3.7

3

(5)

3

2.6 (3.4)
4.5 (6)

1500
8000
5.33:1

14.2 (10.5)

27

0.0093 (0.0819)

133 (292)

38 (84)

AFM-04

3.7 (5)
5.5 (7.5)
4.3 (5.8)
6.7 (9)

1500
8000
5.33:1

23.7 (17.5)

33

0.0213 (0.1881)

165 (364)

59 (130)

AFM-06

5.5 (7.5)
7.5 (10)
6.6 (8.8)
9 (12)

1500
8000
5.33:1

35.6 (26.3)

43

0.2750 (0.2438)

167 (368)

67 (147)

AFL-08

7.5 (10)
11 (15)
9 (12)
13.5 (18)

1500
6000
4:1

47.5 (35.0)

59

0.0550 (0.4867)

313 (688)

94 (207)

AFL-11

11 (15)
15 (20)
13.5 (18)
18 (24)

1500
6000
4:1

71 (52.5)

91

0.0700 (0.6195)

335 (737)

108 (238)

Single winding configuration for single speed range

Peak-to-peak vibration less than 3 microns (0.00012 inch-
es)

Less than 75dB (A Scale)

8 pole brushless resolver – 65,536 counts/revolution

0

°

to 40

°

C (+32

°

to +104

°

F)

Horizontal or vertical. Foot or flange mounting available

4

A04

6

27

Drive Model Number 8510A -

AC Input Voltage

Required AC Input

30 Minute Rating-kVA

Rated Output Current

30 Minute-Amperes

Power Control Method

Motor Braking Method

Input Command

Speed Control Range

Speed Regulation

Velocity Loop Bandwidth

Programming System

Drive Enclosure Type

Drive Weight

kg (lb)

Allowable Vibration

Rated Ambient Temperature

Storage Temperature

A04

9

33

A06

12

43

A11

17

59

PWM inverter using IGBT power devices

Power regeneration to the AC line

±

10V DC, 0-10V DC with Fwd/Rev input, 16 bit binary or BCD digital command

0 to 30,000 rpm, velocity resolution greater than 1:2,000,000

Transient change < 0.4% of max speed, steady state change < 0.025% (load: 10%-100%)

Up to 50 Hz (load and motor dependent)

Integral 2 line by 16 character backlit LCD display and 4 button keypad

Open style (IP-00) for mounting in another enclosure, heat sinks extend outside enclosure

Less than 0.5 G

0 to 55

°

C (32 to 131

°

F) inside enclosure, 0 to 40

°

C (32 to 104

°

F) at heat sinks

0 to 65

°

C (32 to 149

°

F)

A11

22

91

200 to 220V AC (

±

10%) at 50/60 Hz. (

±

1 Hz) and 230V AC (

±

10%) at 60 Hz. (

±

1

Hz)

14 (31)

14 (31)

15 (33)

26 (57)

26 (57)

Notes: see page 2