Specifications, Chapter – Rockwell Automation 8510 AC Spindle Drive System User Manual User Manual
Page 13

2
Chapter
2-9
Specifications
Chapter Objectives
Chapter 2 provides the specifications for the 8510 AC Spindle Drive
System. Specifications have been grouped by type of motor.
Standard Single Speed 1327AC Motor & 8510 Drive
Motor
1327AC -
Output Power Rating
S1 - Continuous - kW (HP)
S2 - 30 Minute - kW (HP)
1
S6 - 60% Duty - kW (HP)
2
1 Minute Peak - kW (HP)
Rated Speed
Base RPM
Maximum RPM
Constant Power/Speed Range
Rated Torque
Continuous N-m (lb-ft)
Rated Current
30 Minute Output Amperes
Rotor Inertia
kg-m
2
(lb.-in.-s
2
)
Bearing Load
Max. Radial - kg (lb)
Motor Weight
kg (lbs.)
Electrical Design
Vibration
Audible Noise
Feedback Device
Rated Ambient Temperature
Possible Mounting Methods
AFM-02
2.2 (3)
3.7
3
(5)
3
2.6 (3.4)
4.5 (6)
1500
8000
5.33:1
14.2 (10.5)
27
0.0093 (0.0819)
133 (292)
38 (84)
AFM-04
3.7 (5)
5.5 (7.5)
4.3 (5.8)
6.7 (9)
1500
8000
5.33:1
23.7 (17.5)
33
0.0213 (0.1881)
165 (364)
59 (130)
AFM-06
5.5 (7.5)
7.5 (10)
6.6 (8.8)
9 (12)
1500
8000
5.33:1
35.6 (26.3)
43
0.2750 (0.2438)
167 (368)
67 (147)
AFL-08
7.5 (10)
11 (15)
9 (12)
13.5 (18)
1500
6000
4:1
47.5 (35.0)
59
0.0550 (0.4867)
313 (688)
94 (207)
AFL-11
11 (15)
15 (20)
13.5 (18)
18 (24)
1500
6000
4:1
71 (52.5)
91
0.0700 (0.6195)
335 (737)
108 (238)
Single winding configuration for single speed range
Peak-to-peak vibration less than 3 microns (0.00012 inch-
es)
Less than 75dB (A Scale)
8 pole brushless resolver – 65,536 counts/revolution
0
°
to 40
°
C (+32
°
to +104
°
F)
Horizontal or vertical. Foot or flange mounting available
4
A04
6
27
Drive Model Number 8510A -
AC Input Voltage
Required AC Input
30 Minute Rating-kVA
Rated Output Current
30 Minute-Amperes
Power Control Method
Motor Braking Method
Input Command
Speed Control Range
Speed Regulation
Velocity Loop Bandwidth
Programming System
Drive Enclosure Type
Drive Weight
kg (lb)
Allowable Vibration
Rated Ambient Temperature
Storage Temperature
A04
9
33
A06
12
43
A11
17
59
PWM inverter using IGBT power devices
Power regeneration to the AC line
±
10V DC, 0-10V DC with Fwd/Rev input, 16 bit binary or BCD digital command
0 to 30,000 rpm, velocity resolution greater than 1:2,000,000
Transient change < 0.4% of max speed, steady state change < 0.025% (load: 10%-100%)
Up to 50 Hz (load and motor dependent)
Integral 2 line by 16 character backlit LCD display and 4 button keypad
Open style (IP-00) for mounting in another enclosure, heat sinks extend outside enclosure
Less than 0.5 G
0 to 55
°
C (32 to 131
°
F) inside enclosure, 0 to 40
°
C (32 to 104
°
F) at heat sinks
0 to 65
°
C (32 to 149
°
F)
A11
22
91
200 to 220V AC (
±
10%) at 50/60 Hz. (
±
1 Hz) and 230V AC (
±
10%) at 60 Hz. (
±
1
Hz)
14 (31)
14 (31)
15 (33)
26 (57)
26 (57)
Notes: see page 2