beautypg.com

Rockwell Automation 8510 AC Spindle Drive System User Manual User Manual

Page 94

background image

Wiring

Chapter 8

8-90

Figure 8.9
Orient Feedback Wiring

CN2-1

FG1

CN2-19

AA

CN2-13

AA Return

CN2-18

CN2-12

AB

AB Return

CN2-17

CN2-11

AZ

AZ Return

CN2-5

+12V DC

CN2-3

GND

Mag

Sensor

CN2-1

FG1

CN2-16

DA

CN2-10

GND

CN2-15

CN2-9

DB

GND

CN2-14

CN2-8

DZ

GND

CN2-5

+12V DC

CN2-4

GND

845T

Encoder

845T Wiring

High Resolution Magnetic Sensor Wiring

Dual Winding Motor Contactor Control Wiring

When a dual winding 1327AD series motor is used with the 8510, the user
must supply two power contactors that will be used to switch the motor
between the

and Y winding configurations. In addition, a 24V DC power

source must be supplied to operate the contactors. Refer to Table 7.A for
the specific contactors that are required for each drive size. The drive will
control the operation of these contactors through the 20 pin CN1 connector
(see Figure 7.3 for location).

The interface cable for this function requires four twisted pairs. The
recommended cable is:

Madison #08CFJ00004 (4 twisted pairs with shield, #24 AWG)

Three termination options are available for the CNl connector: l) a mating
connector kit, 2) a termination panel, and 3) an interface cable assembly.
The following table shows the I/O function assignment for each of these
termination options.