Enter Your Values Here
Load Initial Configuration Values
Chapter 7
7-13
Worksheet 7ĆE(continued)
Injection Configuration Block (INC)
Control Word ProĆSet 600 Addr. Value
Description
Units
INC05
N44:1
1000
Minimum ERC PercentageĆĆVelocity
Percent
8
INC06
N44:2
1000
Minimum ERC PercentageĆĆPressure
Percent
8
INC09
N44:5
*
Output #1 SetĆoutput Value During Profile
Percent Signal Output
4
INC10
N44:6
*
Output #2 SetĆoutput Value During Profile
Percent Signal Output
4
INC11
N44:7
*
Output #3 SetĆoutput Value During Profile
Percent Signal Output
4
INC12
N44:8
*
Output #4 SetĆoutput Value During Profile
Percent Signal Output
4
INC17
N44:13
0
Output #1 Acceleration Ramp Rate During Profile
Percent Signal Output per Second
5
INC18
N44:14
0
Output #2 Acceleration Ramp Rate During Profile
Percent Signal Output per Second
5
INC19
N44:15
0
Output #3 Acceleration Ramp Rate During Profile
Percent Signal Output per Second
5
INC20
N44:16
0
Output #4 Acceleration Ramp Rate During Profile
Percent Signal Output per Second
5
INC25
N44:21
0
Output #1 Deceleration Ramp Rate During Profile
Percent Signal Output per Second
5
INC26
N44:22
0
Output #2 Deceleration Ramp Rate During Profile
Percent Signal Output per Second
5
INC27
N44:23
0
Output #3 Deceleration Ramp Rate During Profile
Percent Signal Output per Second
5
INC28
N44:24
0
Output #4 Deceleration Ramp Rate During Profile
Percent Signal Output per Second
5
INC41
N44:37
0
Pressure Minimum Control Limit
Pressure
3
INC42
N44:38
*
Pressure Maximum Control Limit
Pressure
3
INC43
N44:39
*
Selected Pressure Valve, Output for Minimum
Percent Signal Output
4
INC44
N44:40
*
Selected Pressure Valve, Output for Maximum
Percent Signal Output
4
INC45
N44:41
0
Velocity Minimum Control Limit
Velocity along Axis
2
INC46
N44:42
*
Velocity Maximum Control Limit
Velocity along Axis
2
INC47
N44:43
*
Selected Velocity Valve, Output for Minimum
Percent Signal Output
4
INC48
N44:44
*
Selected Velocity Valve, Output for Maximum
Percent Signal Output
4
INC49
N44:45
100
Proportional Gain for Pressure Control
None
INC50
N44:46
400
Integral Gain for Pressure Control
Inverse Time (Algorithm)
6
INC51
N44:47
0
Derivative Gain for Pressure Control
Time (Algorithm)
7
INC52
N44:48
200
Proportional Gain for Velocity Control
Inverse Time (Algorithm)
6
INC53
N44:49
0
Feed Forward Gain for Velocity Control
None
INC57
N44:53
0
Profile High Pressure Alarm Setpoint
Pressure
3
2
Velocity along Axis
3
Pressure
4
Percent Signal Output
00.00 to 99.99 inches per second 0000 to 9999 PSI 00.00 to 99.99
000.0 to 999.9 millimeters per second 000.0 to 999.9 Bar
5
Percent Signal Output per Second
6
Inverse Time (Algorithm)
7
Time (Algorithm)
8
Percent
0000 to 9999 00.00 to 99.99 Minutes (ISA) 00.00 to 99.99 Minutes (ISA) 00.00 to 99.99
00.00 to 99.99 Seconds (AĆB) 00.00 to 99.99 Seconds (AĆB)
* Refer to the appropriate section later in this chapter for information on this parameter