8ć36, Enter and download your worksheet values – Rockwell Automation 1771-QDC, D17716.5.86(Passport) PLASTIC MOLDING MODULE User Manual
Page 157

Load Initial Profile Values
Chapter 8
8-36
4.
Enter your FOC end-of-segment position setpoints for OPC11, 14,
and 17 on Worksheet 8-E.
We entered zero for the remaining position setpoints on Worksheet 8-E.
The valve spanning procedures in chapter 9 require these initial values.
We help you select correct final values for your application in chapter 10.
for additional information, refer to Section 3 of the Plastic Molding
Module Reference Manual (publication 1771-6.5.88).
Mold Open Dwell Timer Preset
(OPC63)
We entered zero for the mold open dwell timer preset.
The valve spanning procedures in chapter 9 require this initial value. We
help you select correct final values for your application in chapter 10. For
additional information, refer to Section 3 of the Plastic Molding Module
Reference Manual (publication 1771-6.5.88).
After you determine initial values and enter them on Worksheet 8-E, you
are ready to proceed.
1.
Enter all worksheet values into your PLC-5 data table.
Important: Be sure that you have not altered any setpoints, and that you
have entered each and every setpoint exactly as on the worksheet.
2.
Use the procedure described in chapter 4 to download command
blocks to the QDC module. We repeat the OPC block download data.
Block to
Download:
ProĆSet 600
Block ID:
Download
Command Bit:
Companion
Block:
OPC
21
B21/20
none
3.
Check SYS61 and SYS62 for programming errors. Correct as
needed.