Algorithm Selection
IPC Block Identifier
00 = Vel/Pos
01 = Vel/Pos (pressure limited)
10 = Press/Pos
11 = Press/Time
Sign of Velocity Offset
0 = Positive
1 = Negative
Velocity Units
0 = Parameters in Percent Velocity"
1 = Parameters in Inches (mm)/Sec
Sign of Pressure Offset
0 = Positive
1 = Negative
0 = Vel/Pos Closed Loop
1 = Open Loop
0 = Vel/Pos (limited) Closed Loop
1 = Open Loop
0 = Press/Pos Closed Loop
1 = Open Loop
0 = Press/Time Closed Loop
1 = Open Loop
0 = ERC On for Vel/Pos
1 = ERC Off
0 = ERC On for Vel/Pos (limited)
1 = ERC Off
0 = ERC On for Press/Pos
1 = ERC Off
0 = ERC On for Press/Time
1 = ERC Off
Code:
Your value
Required initial value
loaded by ProĆSet 600
0 or 1
Enter Your Values Here
Load Initial Profile Values
Chapter 8
8-10
Worksheet 8ĆB
Injection Profile Block (IPC)
Control Word IPC01ĆBxx
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
ProĆSet 600 Addr. B38/bit
79
78
77
76
75
74
73
72
71
70
69
68
67
66
65
64
Value
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
1
Control Word IPC03ĆBxx
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
ProĆSet 600 Addr. B38/bit
111 110 109 108 107 106 105 104 103 102 101 100
99
98
97
96
Value
0
1
0
0
0
0
0
0
0
0
0
0
0
0
1
1
Control Word IPC04ĆBxx
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
00
ProĆSet 600 Addr. B38/bit
127 126 125 124 123 122 121 120 119 118 117 116 115 114 113 112
Value
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
Control Word ProĆSet 600 Addr. Value
Description
Units
IPC09
N44:65
*
Segment 1 Velocity Setpoint
Velocity
4
IPC10
N44:66
*
Segment 1 Pressure Setpoint
Pressure
3
IPC11
N44:67
*
EndĆof Segment 1 Position Setpoint
Distance from MoldĆend
2
IPC12
N44:68
100
Segment 1 Time Setpoint
Time
1
IPC13
N44:69
*
Segment 2 Velocity Setpoint
Velocity
4
IPC14
N44:70
*
Segment 2 Pressure Setpoint
Pressure