Blank worksheets appendix a – Rockwell Automation 1771-QDC, D17716.5.86(Passport) PLASTIC MOLDING MODULE User Manual
Page 249

Enter Your PressureĆalarm and TimeĆdelay Values Here
Enter Your Initial Values Here
Blank Worksheets
Appendix A
A-4
Worksheet 3ĆG
PressureĆalarm and TimeĆdelay Setpoints
Control Word
ProĆSet 600 Addr. Value
Description
Units
MCC21
N40:17
Screw PressureĆalarm Setpoint
Ram (screw) Pressure
2
MCC22
N40:18
ScrewĆpressure TimeĆdelay Setpoint
Time Measured in Seconds
1
MCC35
N40:31
Clamp PressureĆalarm Setpoint
Clamp Pressure
2
MCC36
N40:32
ClampĆpressure TimeĆdelay Setpoint
Time Measured in Seconds
1
1
Time Measured in Seconds
2
Pressure
00.00 to 00.99
0000 to 9999 PSI 000.0 to 999.9 Bar
Worksheet 5ĆA
Ram (screw) and Clamp Jog Configuration Values
Control Word
ProĆSet 600 Addr. Value
Description
Units
Inject, Forward Jog
JGC17
N40:73
Set Output Values Output #1
% Signal Output
1
JGC18
N40:74
Output #2
% Signal Output
1
JGC19
N40:75
Output #3
% Signal Output
1
JGC20
N40:76
Output #4
% Signal Output
1
Inject, Reverse Jog
JGC25
N40:81
Set Output Values Output #1
% Signal Output
1
JGC26
N40:82
Output #2
% Signal Output
1
JGC27
N40:83
Output #3
% Signal Output
1
JGC28
N40:84
Output #4
% Signal Output
1
Clamp, Forward Jog
JGC33
N40:89
Set Output Values Output #1
% Signal Output
1
JGC34
N40:90
Output #2
% Signal Output
1
JGC35
N40:91
Output #3
% Signal Output
1
JGC36
N40:92
Output #4
% Signal Output
1
Clamp, Reverse Jog
JGC41
N40:97
Set Output Values Output #1
% Signal Output
1
JGC42
N40:98
Output #2
% Signal Output
1
JGC43
N40:99
Output #3
% Signal Output
1
JGC44
N40:100
Output #4
% Signal Output
1
Jog Pressure Alarms
JGC06
N40:62
Ram Jog Pressure, Alarm Setpoint
Ram (screw) Pressure
2
JGC07
N40:63
Clamp Jog Pressure Alarm Setpoint
Clamp Pressure
2
1
% Signal Output
2
Pressure
00.00 to 99.99 %
0000 to 9999 PSI 000.0 to 999.9 Bar