Load initial configuration values chapter 7 – Rockwell Automation 1771-QDC, D17716.5.86(Passport) PLASTIC MOLDING MODULE User Manual
Page 90
Enter Your Values Here
Load Initial Configuration Values
Chapter 7
7-9
Worksheet 7ĆC (continued)
Third Clamp Close Configuration Block (TCC)
Control Word ProĆSet 600 Addr. Value
Description
Units
TCC05
N43:121
1000
Minimum ERC PercentageĆĆVelocity
Percent
8
TCC06
N43:122
1000
Minimum ERC PercentageĆĆPressure
Percent
8
TCC08
N43:124
0
Profile Watchdog Timer Preset
Time
1
TCC09
N43:125
*
Output #1 SetĆOutput Value during Profile
Percent Signal Output
4
TCC10
N43:126
*
Output #2 SetĆOutput Value during Profile
Percent Signal Output
4
TCC11
N43:127
*
Output #3 SetĆOutput Value during Profile
Percent Signal Output
4
TCC12
N43:128
*
Output #4 SetĆOutput Value during Profile
Percent Signal Output
4
TCC17
N43:133
0
Output #1 Acceleration Ramp Rate during Profile
Percent Signal Output per Second
5
TCC18
N43:134
0
Output #2 Acceleration Ramp Rate during Profile
Percent Signal Output per Second
5
TCC19
N43:135
0
Output #3 Acceleration Ramp Rate during Profile
Percent Signal Output per Second
5
TCC20
N43:136
0
Output #4 Acceleration Ramp Rate during Profile
Percent Signal Output per Second
5
TCC25
N43:141
0
Output #1 Deceleration Ramp Rate during Profile
Percent Signal Output per Second
5
TCC26
N43:142
0
Output #2 Deceleration Ramp Rate during Profile
Percent Signal Output per Second
5
TCC27
N43:143
0
Output #3 Deceleration Ramp Rate during Profile
Percent Signal Output per Second
5
TCC28
N43:144
0
Output #4 Deceleration Ramp Rate during Profile
Percent Signal Output per Second
5
TCC33
N43:149
*
Output #1 SetĆOutput Value at EndĆof Profile
Percent Signal Output
4
TCC34
N43:150
*
Output #2 SetĆOutput Value at EndĆof Profile
Percent Signal Output
4
TCC35
N43:151
*
Output #3 SetĆOutput Value at EndĆof Profile
Percent Signal Output
4
TCC36
N43:152
*
Output #4 SetĆOutput Value at EndĆof Profile
Percent Signal Output
4
TCC41
N43:157
0
Pressure Minimum Control Limit
Pressure
3
TCC42
N43:158
*
Pressure Maximum Control Limit
Pressure
3
TCC43
N43:159
*
Selected Pressure Valve, Output for Minimum
Percent Signal Output
4
TCC44
N43:160
*
Selected Pressure Valve, Output for Maximum
Percent Signal Output
4
TCC45
N43:161
0
Velocity Minimum Control Limit
Velocity along Axis
2
TCC46
N43:162
*
Velocity Maximum Control Limit
Velocity along Axis
2
TCC47
N43:163
*
Selected Velocity Valve, Output for Minimum
Percent Signal Output
4
TCC48
N43:164
*
Selected Velocity Valve, Output for Maximum
Percent Signal Output
4
TCC49
N43:165
100
Proportional Gain for Pressure Control
None
TCC50
N43:166
400
Integral Gain for Pressure Control
Inverse Time (Algorithm)
6
TCC51
N43:167
0
Derivative Gain for Pressure Control
Time (Algorithm)
7
TCC52
N43:168
200
Proportional Gain for Velocity Control
Inverse Time (Algorithm)
6
TCC53
N43:169
0
Feed Forward Gain for Velocity Control
None
TCC57
N43:173
0
Profile High Pressure Alarm Setpoint
Pressure
3
1
Time
2
Velocity along Axis
3
Pressure
4
Percent Signal Output
00.00 to 99.99 Seconds 00.00 to 99.99 Inches per Second 0000 to 9999 PSI 00.00 to 99.99
000.0 to 999.9 Millimeters per Second 000.0 to 999.9 Bar
5
Percent Signal Output per Second
6
Inverse Time (Algorithm)
7
Time (Algorithm)
8
Percent
0000 to 9999 00.00 to 99.99 Minutes (ISA) 00.00 to 99.99 Minutes (ISA) 00.00 to 99.99
00.00 to 99.99 Seconds (AĆB) 00.00 to 99.99 Seconds (AĆB)
* Refer to the appropriate section later in this chapter for information on this parameter