Blank worksheets appendix a – Rockwell Automation 1771-QDC, D17716.5.86(Passport) PLASTIC MOLDING MODULE User Manual
Page 247
Select Output 1 Range with bits 01, 00
Select Output 2 Range with bits 03, 02
Select Output 3 Range with bits 05, 04
Select Output 4 Range with bits 07, 06
Output Range
-10 to +10V dc
0
0
0 to +10V dc
0
1
4 to 20 mA
1
0
Not connected
1
1
Enter Your Initial Values Here
Blank Worksheets
Appendix A
A-2
Worksheet 3ĆC
Selecting Output Ranges for your Valves
Control Word MCC04ĆBxx
15
14 13 12 11
10
09 08 07 06 05 04 03 02 01 00
ProĆSet 600 Addr. B34/bit
575 574 573 572 571 570 569 568 567 566 565 564 563 562 561 560
Value
1
1
1
1
1
1
1
1
Example: If you select 0-10V dc for all four output ranges: MCC04 = 11111111 01010101.
Important: Software output selections must match jumper settings for each respective output.
Worksheet 3ĆD
Determining Initial SensorĆconfiguration Values
Input
Line
Control Word
ProĆSet 600 Addr. Value
Description
Units
1
1
MCC09
N40:5
Minimum Screw Position
Screw Axis Measured from zero
1
2
MCC10
N40:6
Maximum Screw Position
Screw Axis Measured from zero
1
3
MCC11
N40:7
Analog Signal @ Min Screw Position
Input Signal Range
2
4
MCC12
N40:8
Analog Signal @ Max Screw Position
Input Signal Range
2
2
5
MCC17
N40:13
Minimum Screw Pressure
Screw Pressure
3
6
MCC18
N40:14
Maximum Screw Pressure
Screw Pressure
3
7
MCC19
N40:15
Analog Signal @ Min Screw Pressure
Input Signal Range
2
8
MCC20
N40:16
Analog Signal @ Max Screw Pressure
Input Signal Range
2
3
9
MCC23
N40:19
Minimum Clamp Position
Clamp Axis Measured from zero
1
10
MCC24
N40:20
Maximum Clamp Position
Clamp Axis Measured from zero
1
11
MCC25
N40:21
Analog Signal @ Min Clamp Position
Input Signal Range
2
12
MCC26
N40.22
Analog Signal @ Max Clamp Position
Input Signal Range
2
4
13
MCC31
N40:27
Minimum Clamp Pressure
Clamp Pressure
3
14
MCC32
N40:28
Maximum Clamp Pressure
Clamp Pressure
3
15
MCC33
N40:29
Analog Signal @ Min Clamp Pressure
Input Signal Range
2
16
MCC34
N40:30
Analog Signal @ Max Clamp Pressure Input Signal Range
2
1
Incremental Distance
2
Input Signal Range
3
Pressure
00.00 to 99.99in
00.00 to 10.00VDC or
0000 to 9999 PSI
000.0 to 999.9mm
01.00 to 05.00VDC or
000.0 to 999.9 Bar
04.00 to 20.00MADC