Rockwell Automation 1771-QDC, D17716.5.86(Passport) PLASTIC MOLDING MODULE User Manual
Page 74
Select Command and Status Bits
to Sequence Machine Operation
Chapter 6
6-3
Table 6.C
Status and Command Bit Interaction for Automatic Functions
For this
Profile/Movement:
During Execution
this bit in B34 is:
At Completion
this bit in B34 is:
At completion
If this
Then this
command bit is:
status bit is:
SET
RESET
SET
RESET
also SET
also SET
1st Clamp Close
SYS21ĆB00 SYS02ĆB00 SYS02ĆB00 SYS21ĆB00 CPC03ĆB08
SYS22ĆB00
2nd Clamp Close
SYS21ĆB01 SYS02ĆB01 SYS02ĆB01 SYS21ĆB01 CPC03ĆB09
SYS22ĆB01
3rd Clamp Close
SYS21ĆB02 SYS02ĆB02 SYS02ĆB02 SYS21ĆB02 CPC03ĆB10
SYS22ĆB02
Low Pressure Close SYS21ĆB03 SYS02ĆB03 SYS02ĆB03 SYS21ĆB03 ---
SYS22ĆB03
Injection
SYS21ĆB04 SYS02ĆB04 SYS02ĆB04 SYS21ĆB04 ---
---
Pack
SYS21ĆB05 SYS02ĆB05 SYS02ĆB05 SYS21ĆB05 ---
---
Hold
SYS21ĆB06 SYS02ĆB06 SYS02ĆB06 SYS21ĆB06 HPC03ĆB08
SYS22ĆB06
PreĆdecompression
SYS21ĆB07 SYS02ĆB07 SYS02ĆB07 SYS21ĆB07 HPC03ĆB09
SYS22ĆB07
Plastication
SYS21ĆB08 SYS02ĆB08 SYS02ĆB08 SYS21ĆB08 PPC03ĆB08
SYS22ĆB08
PostĆdecompression SYS21ĆB09 SYS02ĆB09 SYS02ĆB09 SYS21ĆB09 ---
SYS22ĆB09
1st Clamp Open
SYS21ĆB10 SYS02ĆB10 SYS02ĆB10 SYS21ĆB10 OPC03ĆB08
SYS22ĆB10
2nd Clamp Open
SYS21ĆB11 SYS02ĆB11 SYS02ĆB11 SYS21ĆB11 OPC03ĆB09
SYS22ĆB11
3rd Clamp Open
SYS21ĆB12 SYS02ĆB12 SYS02ĆB12 SYS21ĆB12 OPC03ĆB10
SYS22ĆB12
Clamp Open Slow
SYS21ĆB13 SYS02ĆB13 SYS02ĆB13 SYS21ĆB13 ---
SYS22ĆB13