Load Initial Configuration Values
Chapter 7
7-32
Table 7.A
SetĆoutput Values for Unselected Valves
If the unselected
valve controls:
and the unselected
valve type is:
and during profile,
valve action is:
and during profile,
you require:
Then Enter:
Pressure
UniĆdirectional
Direct acting
Maximum Pressure 9999
Pressure
UniĆdirectional
Direct acting
Medium Pressure
7500 to
5000
Pressure
UniĆdirectional
Direct acting
Low Pressure
5000 to
2500
Pressure
UniĆdirectional
Direct acting
Minimum Pressure
0
Pressure
UniĆdirectional
Reverse acting
Maximum Pressure 0
Pressure
UniĆdirectional
Reverse acting
Medium Pressure
2500 to
5000
Pressure
UniĆdirectional
Reverse acting
Low Pressure
5000 to
7500
Pressure
UniĆdirectional
Reverse acting
Minimum Pressure
9999
Flow
UniĆdirectional
Direct acting
Maximum Flow
9999
Flow
UniĆdirectional
Direct acting
Medium Flow
7500 to
5000
Flow
UniĆdirectional
Direct acting
Low Flow
5000 to
2500
Flow
UniĆdirectional
Direct acting
Minimum Flow
0
Flow
UniĆdirectional
Reverse acting
Maximum Flow
0
Flow
UniĆdirectional
Reverse acting
Medium Flow
2500 to
5000
Flow
UniĆdirectional
Reverse acting
Low Flow
5000 to
7500
Flow
UniĆdirectional
Reverse acting
Minimum Flow
9999
Flow
BiĆdirectional
Direct acting
Maximum Flow
9999
Flow
BiĆdirectional
Direct acting
Medium Flow
8750 to
7500
Flow
BiĆdirectional
Direct acting
Low Flow
7500 to
6250
Flow
BiĆdirectional
Direct acting
Minimum Flow
5000
Flow
BiĆdirectional
Reverse acting
Maximum Flow
0
Flow
BiĆdirectional
Reverse acting
Medium Flow
1250 to
2500
Flow
BiĆdirectional
Reverse acting
Low Flow
2500 to
3750
Flow
BiĆdirectional
Reverse acting
Minimum Flow
5000
Important: Valve spanning procedures in chapter 9 require unselected
valves be driven at signal levels representative of a normal production run.
We discuss process considerations that impend changing these values in
chapter 10. Changing these values may require you to re-span your valves.
Enter all set-output values for unselected valves in worksheets 7-A – 7-L.