9ć36, Span your plastication pressure valve, Span your valves chapter 9 – Rockwell Automation 1771-QDC, D17716.5.86(Passport) PLASTIC MOLDING MODULE User Manual
Page 193: Confirm critical values
![background image](/manuals/579349/193/background.png)
Span Your Valves
Chapter 9
9-36
We recommend that you span your plastication pressure valve for optimum
plastication performance in four parts:
Confirm critical values
Span your plastication pressure valve
Test valve linearity with a plastication backpressure vs. position profile
Set the profile pressure alarm
Important: You may omit the next three parts of this section if you have
the right information on valve spanning. Many injection molding machine
OEMs and hydraulic valve manufacturers provide data on spanning the
working range of valves used on their machines. If this information is
available from your OEM for your machine’s plastication pressure valve,
enter the values into pressure control limits PLC41-44 and proceed to Set
the Profile Pressure Alarm.
Confirm Critical Values
Important: Confirm that all entries you made for configuration values
(chapter 7) and profile values (chapter 8) are as follows:
On Worksheet Confirm Your Configuration
With These Words or Bits
ProĆSet Addr
7ĆH
QDC module output to which you connected
your plastication pressure control valve
PLC02ĆB06, B05, B04
B38/404Ć406
SetĆoutput values for unselected valves
PLC09Ć12 = your values
N44:365Ć368
All ramping is disabled with zero ramp rates
PLC17Ć20 = 0
PLC25Ć28 = 0
N44:373Ć376
N44:381Ć384
EndĆofĆprofile SetĆoutput values
PLC33Ć36 for zero output
N44:389Ć392
Pressure limits:
Minimum Pressure Control Limit
Maximum Pressure Control Limit
Selected Pressure Valve, Output for Min
Selected Pressure Valve, Output for Max
PLC41 = 0
PLC42 = max attainable backpressure
PLC43 = your value
PLC44 = your value
N44:397
N44:398
N44:399
N44:400
8ĆD
Backpressure vs Position algorithm
PPC03ĆB00 = 0
B38/480
Logical bridge to stop and set outputs before
postĆdecompression
PPC03ĆB08 = 1
B38/488
OpenĆloop control
PPC04ĆB01 = B00 = 1
B38/496, 497
Expert Response Compensation (ERC) = Off
PPC04ĆB09 = B08 = 1
B38/504, 505
Backpressure setpoints
PPC10,14, 18, 22, 26, 30, 34, 38, 42,
46, 50 all equal to max desired
backpressure
start @ N44:426
end @ N44:466
Position setpoints
PPC11,15,19,23,27,31,35,39,43,47
equal segments over shot size
start @ N44:427
end @ N44:463
Shot size
PPC62 = typical for your machine
N44:478
If these are not your current values, we suggest that you correct them now
and download them using the download procedure discussed in chapter 4.
Span Your Plastication
Pressure Valve