Load initial configuration values chapter 7 – Rockwell Automation 1771-QDC, D17716.5.86(Passport) PLASTIC MOLDING MODULE User Manual
Page 104

Enter Your Values Here
Load Initial Configuration Values
Chapter 7
7-23
Worksheet 7ĆJ (continued)
Second Clamp Open Configuration Block (SOC)
Control Word ProĆSet 600 Addr. Value
Description
Units
SOC05
N43:361
1000
Minimum ERC PercentageĆĆVelocity
Percent
8
SOC06
N43:362
1000
Minimum ERC PercentageĆĆPressure
Percent
8
SOC08
N43:364
0
Profile Watchdog Timer Preset
Time
1
SOC09
N43:365
*
Output #1 SetĆOutput Value during Profile
Percent Signal Output
3
SOC10
N43:366
*
Output #2 SetĆOutput Value during Profile
Percent Signal Output
3
SOC11
N43:367
*
Output #3 SetĆOutput Value during Profile
Percent Signal Output
3
SOC12
N43:368
*
Output #4 SetĆOutput Value during Profile
Percent Signal Output
3
SOC17
N43:373
0
Output #1 Acceleration Ramp Rate during Profile
Percent Signal Output per Second
4
SOC18
N43:374
0
Output #2 Acceleration Ramp Rate during Profile
Percent Signal Output per Second
4
SOC19
N43:375
0
Output #3 Acceleration Ramp Rate during Profile
Percent Signal Output per Second
4
SOC20
N43:376
0
Output #4 Acceleration Ramp Rate during Profile
Percent Signal Output per Second
4
SOC25
N43:381
0
Output #1 Deceleration Ramp Rate during Profile
Percent Signal Output per Second
4
SOC26
N43:382
0
Output #2 Deceleration Ramp Rate during Profile
Percent Signal Output per Second
4
SOC27
N43:383
0
Output #3 Deceleration Ramp Rate during Profile
Percent Signal Output per Second
4
SOC28
N43:384
0
Output #4 Deceleration Ramp Rate during Profile
Percent Signal Output per Second
4
SOC33
N43:389
*
Output #1 SetĆOutput Value at EndĆof Profile
Percent Signal Output
3
SOC34
N43:390
*
Output #2 SetĆOutput Value at EndĆof Profile
Percent Signal Output
3
SOC35
N43:391
*
Output #3 SetĆOutput Value at EndĆof Profile
Percent Signal Output
3
SOC36
N43:392
*
Output #4 SetĆOutput Value at EndĆof Profile
Percent Signal Output
3
SOC41
N43:397
0
Pressure Minimum Control Limit
Pressure
2
SOC42
N43:398
*
Pressure Maximum Control Limit
Pressure
2
SOC43
N43:399
*
Selected Pressure Valve, Output for Minimum
Percent Signal Output
3
SOC44
N43:400
*
Selected Pressure Valve, Output for Maximum
Percent Signal Output
3
SOC45
N43:401
0
Velocity Minimum Control Limit
Velocity along Axis
5
SOC46
N43:402
*
Velocity Maximum Control Limit
Velocity along Axis
5
SOC47
N43:403
*
Selected Velocity Valve, Output for Minimum
Percent Signal Output
3
SOC48
N43:404
*
Selected Velocity Valve, Output for Maximum
Percent Signal Output
3
SOC49
N43:405
100
Proportional Gain for Pressure Control
None
SOC50
N43:406
400
Integral Gain for Pressure Control
Inverse Time (Algorithm)
6
SOC51
N43:407
0
Derivative Gain for Pressure Control
Time (Algorithm)
7
SOC52
N43:408
200
Proportional Gain for Velocity Control
Inverse Time (Algorithm)
6
SOC53
N43:409
0
Feed Forward Gain for Velocity Control
None
SOC57
N43:413
0
Profile High Pressure Alarm Setpoint
Pressure
2
1
Time
2
Pressure
3
Percent Signal Output
4
Percent Signal Output per Second
00.00 to 99.99 Seconds 0000 to 9999 PSI 00.00 to 99.99 0000 to 9999
000.0 to 999.9 Bar
5
Velocity along Axis
6
Inverse Time (Algorithm)
7
Time (Algorithm)
8
Percent
00.00 to 99.99 Inches per Second 00.00 to 99.99 Minutes (ISA) 00.00 to 99.99 Minutes (ISA) 00.00 to 99.99
000.0 to 999.9 Millimeters per Second 00.00 to 99.99 Seconds (AĆB) 00.00 to 99.99 Seconds (AĆB)
* Refer to the appropriate section later in this chapter for information on this parameter