Blank worksheets appendix a – Rockwell Automation 1771-QDC, D17716.5.86(Passport) PLASTIC MOLDING MODULE User Manual
Page 252
Enter Your Values Here
Blank Worksheets
Appendix A
A-7
Worksheet 7ĆA (continued)
First Clamp Close Configuration Block (FCC)
Control Word ProĆSet 600 Addr. Value
Description
Units
FCC05
N43:1
Minimum ERC PercentageĆĆVelocity
Percent
8
FCC06
N43:2
Minimum ERC PercentageĆĆPressure
Percent
8
FCC08
N43:4
Profile Watchdog Timer Preset
Time
1
FCC09
N43:5
Output #1 SetĆOutput Value during Profile
Percent Signal Output
4
FCC10
N43:6
Output #2 SetĆOutput Value during Profile
Percent Signal Output
4
FCC11
N43:7
Output #3 SetĆOutput Value during Profile
Percent Signal Output
4
FCC12
N43:8
Output #4 SetĆOutput Value during Profile
Percent Signal Output
4
FCC17
N43:13
Output #1 Acceleration Ramp Rate during Profile
Percent Signal Output per Second
5
FCC18
N43:14
Output #2 Acceleration Ramp Rate during Profile
Percent Signal Output per Second
5
FCC19
N43:15
Output #3 Acceleration Ramp Rate during Profile
Percent Signal Output per Second
5
FCC20
N43:16
Output #4 Acceleration Ramp Rate during Profile
Percent Signal Output per Second
5
FCC25
N43:21
Output #1 Deceleration Ramp Rate during Profile
Percent Signal Output per Second
5
FCC26
N43:22
Output #2 Deceleration Ramp Rate during Profile
Percent Signal Output per Second
5
FCC27
N43:23
Output #3 Deceleration Ramp Rate during Profile
Percent Signal Output per Second
5
FCC28
N43:24
Output #4 Deceleration Ramp Rate during Profile
Percent Signal Output per Second
5
FCC33
N43:29
Output #1 SetĆOutput Value at EndĆof Profile
Percent Signal Output
4
FCC34
N43:30
Output #2 SetĆOutput Value at EndĆof Profile
Percent Signal Output
4
FCC35
N43:31
Output #3 SetĆOutput Value at EndĆof Profile
Percent Signal Output
4
FCC36
N43:32
Output #4 SetĆOutput Value at EndĆof Profile
Percent Signal Output
4
FCC41
N43:37
Pressure Minimum Control Limit
Pressure
3
FCC42
N43:38
Pressure Maximum Control Limit
Pressure
3
FCC43
N43:39
Selected Pressure Valve, Output for Minimum
Percent Signal Output
4
FCC44
N43:40
Selected Pressure Valve, Output for Maximum
Percent Signal Output
4
FCC45
N43:41
Velocity Minimum Control Limit
Velocity along Axis
2
FCC46
N43:42
Velocity Maximum Control Limit
Velocity along Axis
2
FCC47
N43:43
Selected Velocity Valve, Output for Minimum
Percent Signal Output
4
FCC48
N43:44
Selected Velocity Valve, Output for Maximum
Percent Signal Output
4
FCC49
N43:45
Proportional Gain for Pressure Control
None
FCC50
N43:46
Integral Gain for Pressure Control
Inverse Time (Algorithm)
6
FCC51
N43:47
Derivative Gain for Pressure Control
Time (Algorithm)
7
FCC52
N43:48
Proportional Gain for Velocity Control
Inverse Time (Algorithm)
6
FCC53
N43:49
Feed Forward Gain for Velocity Control
None
FCC57
N43:53
Profile High Pressure Alarm Setpoint
Pressure
3
1
Time
2
Velocity along Axis
3
Pressure
4
Percent Signal Output
00.00 to 99.99 Seconds
00.00 to 99.99 Inches per Second
0000 to 9999 PSI
00.00 to 99.99
000.0 to 999.9 Millimeters per Second
000.0 to 999.9 Bar
5
Percent Signal Output per Second
6
Inverse Time (Algorithm)
7
Time (Algorithm)
8
Percent
0000 to 9999
00.00 to 99.99 minutes (ISA)
00.00 to 99.99 minutes (ISA)
00.00 to 99.99
00.00 to 99.99 seconds (AĆB)
00.00 to 99.99 seconds (AĆB)
* Refer to the appropriate section later in this chapter for information on this parameter