Blank worksheets appendix a – Rockwell Automation 1771-QDC, D17716.5.86(Passport) PLASTIC MOLDING MODULE User Manual
Page 272

Enter Your Values Here
Blank Worksheets
Appendix A
A-27
Worksheet 7ĆK (continued)
Third Clamp Open Configuration Block (TOC)
Control Word ProĆSet 600 Addr. Value
Description
Units
TOC05
N43:421
Minimum ERC PercentageĆĆVelocity
Percent
8
TOC06
N43:422
Minimum ERC PercentageĆĆPressure
Percent
8
TOC08
N43:424
Profile Watchdog Timer Preset
Time
1
TOC09
N43:425
Output #1 SetĆOutput Value during Profile
Percent Signal Output
3
TOC10
N43:426
Output #2 SetĆOutput Value during Profile
Percent Signal Output
3
TOC11
N43:427
Output #3 SetĆOutput Value during Profile
Percent Signal Output
3
TOC12
N43:428
Output #4 SetĆOutput Value during Profile
Percent Signal Output
3
TOC17
N43:433
Output #1 Acceleration Ramp Rate during Profile
Percent Signal Output per Second
4
TOC18
N43:434
Output #2 Acceleration Ramp Rate during Profile
Percent Signal Output per Second
4
TOC19
N43:435
Output #3 Acceleration Ramp Rate during Profile
Percent Signal Output per Second
4
TOC20
N43:436
Output #4 Acceleration Ramp Rate during Profile
Percent Signal Output per Second
4
TOC25
N43:441
Output #1 Deceleration Ramp Rate during Profile
Percent Signal Output per Second
4
TOC26
N43:442
Output #2 Deceleration Ramp Rate during Profile
Percent Signal Output per Second
4
TOC27
N43:443
Output #3 Deceleration Ramp Rate during Profile
Percent Signal Output per Second
4
TOC28
N43:444
Output #4 Deceleration Ramp Rate during Profile
Percent Signal Output per Second
4
TOC33
N43:449
Output #1 SetĆOutput Value at EndĆof Profile
Percent Signal Output
3
TOC34
N43:450
Output #2 SetĆOutput Value at EndĆof Profile
Percent Signal Output
3
TOC35
N43:451
Output #3 SetĆOutput Value at EndĆof Profile
Percent Signal Output
3
TOC36
N43:452
Output #4 SetĆOutput Value at EndĆof Profile
Percent Signal Output
3
TOC41
N43:457
Pressure Minimum Control Limit
Pressure
2
TOC42
N43:458
Pressure Maximum Control Limit
Pressure
2
TOC43
N43:459
Selected Pressure Valve, Output for Minimum
Percent Signal Output
3
TOC44
N43:460
Selected Pressure Valve, Output for Maximum
Percent Signal Output
3
TOC45
N43:461
Velocity Minimum Control Limit
Velocity along Axis
5
TOC46
N43:462
Velocity Maximum Control Limit
Velocity along Axis
5
TOC47
N43:463
Selected Velocity Valve, Output for Minimum
Percent Signal Output
3
TOC48
N43:464
Selected Velocity Valve, Output for Maximum
Percent Signal Output
3
TOC49
N43:465
Proportional Gain for Pressure Control
None
TOC50
N43:466
Integral Gain for Pressure Control
Inverse Time (Algorithm)
6
TOC51
N43:467
Derivative Gain for Pressure Control
Time (Algorithm)
7
TOC52
N43:468
Proportional Gain for Velocity Control
Inverse Time (Algorithm)
6
TOC53
N43:469
Feed Forward Gain for Velocity Control
None
TOC57
N43:473
Profile High Pressure Alarm Setpoint
Pressure
2
1
Time
2
Pressure
3
Percent Signal Output
4
Percent Signal Output per Second
00.00 to 99.99 Seconds
0000 to 9999 PSI
00.00 to 99.99
0000 to 9999
000.0 to 999.9 Bar
5
Velocity along Axis
6
Inverse Time (Algorithm)
7
Time (Algorithm)
8
Percent
00.00 to 99.99 Inches per Second
00.00 to 99.99 Minutes (ISA)
00.00 to 99.99 Minutes (ISA)
00.00 to 99.99
000.0 to 999.9 Millimeters per Second
00.00 to 99.99 Seconds (AĆB)
00.00 to 99.99 Seconds (AĆB)
* Refer to the appropriate section later in this chapter for information on this parameter