7-21
Worksheet 7ĆI (continued)
First Clamp Open Configuration Block (FOC)
Control Word ProĆSet 600 Addr. Value
Description
Units
FOC05
N43:301
1000
Minimum ERC PercentageĆĆVelocity
Percent
8
FOC06
N43:302
1000
Minimum ERC PercentageĆĆPressure
Percent
8
FOC08
N43:304
0
Profile Watchdog Timer Preset
Time
1
FOC09
N43:305
*
Output #1 SetĆOutput Value during Profile
Percent Signal Output
4
FOC10
N43:306
*
Output #2 SetĆOutput Value during Profile
Percent Signal Output
4
FOC11
N43:307
*
Output #3 SetĆOutput Value during Profile
Percent Signal Output
4
FOC12
N43:308
*
Output #4 SetĆOutput Value during Profile
Percent Signal Output
4
FOC17
N43:313
0
Output #1 Acceleration Ramp Rate during Profile
Percent Signal Output per Second
5
FOC18
N43:314
0
Output #2 Acceleration Ramp Rate during Profile
Percent Signal Output per Second
5
FOC19
N43:315
0
Output #3 Acceleration Ramp Rate during Profile
Percent Signal Output per Second
5
FOC20
N43:316
0
Output #4 Acceleration Ramp Rate during Profile
Percent Signal Output per Second
5
FOC25
N43:321
0
Output #1 Deceleration Ramp Rate during Profile
Percent Signal Output per Second
5
FOC26
N43:322
0
Output #2 Deceleration Ramp Rate during Profile
Percent Signal Output per Second
5
FOC27
N43:323
0
Output #3 Deceleration Ramp Rate during Profile
Percent Signal Output per Second
5
FOC28
N43:324
0
Output #4 Deceleration Ramp Rate during Profile
Percent Signal Output per Second
5
FOC33
N43:329
*
Output #1 SetĆOutput Value at EndĆof Profile
Percent Signal Output
4
FOC34
N43:330
*
Output #2 SetĆOutput Value at EndĆof Profile
Percent Signal Output
4
FOC35
N43:331
*
Output #3 SetĆOutput Value at EndĆof Profile
Percent Signal Output
4
FOC36
N43:332
*
Output #4 SetĆOutput Value at EndĆof Profile
Percent Signal Output
4
FOC41
N43:337
0
Pressure Minimum Control Limit
Pressure
3
FOC42
N43:338
*
Pressure Maximum Control Limit
Pressure
3
FOC43
N43:339
*
Selected Pressure Valve, Output for Minimum
Percent Signal Output
4
FOC44
N43:340
*
Selected Pressure Valve, Output for Maximum
Percent Signal Output
4
FOC45
N43:341
0
Velocity Minimum Control Limit
Velocity along Axis
2
FOC46
N43:342
*
Velocity Maximum Control Limit
Velocity along Axis
2
FOC47
N43:343
*
Selected Velocity Valve, Output for Minimum
Percent Signal Output
4
FOC48
N43:344
*
Selected Velocity Valve, Output for Maximum
Percent Signal Output
4
FOC49
N43:345
100
Proportional Gain for Pressure Control
None
FOC50
N43:346
400
Integral Gain for Pressure Control
Inverse Time (Algorithm)
6
FOC51
N43:347
0
Derivative Gain for Pressure Control
Time (Algorithm)
7
FOC52
N43:348
200
Proportional Gain for Velocity Control
Inverse Time (Algorithm)
6
FOC53
N43:349
0
Feed Forward Gain for Velocity Control
None
FOC57
N43:353
0
Profile High Pressure Alarm Setpoint
Pressure
3
1
Time
2
Velocity along Axis
3
Pressure
4
Percent Signal Output
00.00 to 99.99 Seconds 00.00 to 99.99 Inches per Second 0000 to 9999 PSI 00.00 to 99.99
000.0 to 999.9 Millimeters per Second 000.0 to 999.9 Bar
5
Percent Signal Output per Second
6
Inverse Time (Algorithm)
7
Time (Algorithm)
8
Percent
0000 to 9999 00.00 to 99.99 Minutes (ISA) 00.00 to 99.99 Minutes (ISA) 00.00 to 99.99
00.00 to 99.99 Seconds (AĆB) 00.00 to 99.99 Seconds (AĆB)
* Refer to the appropriate section later in this chapter for information on this parameter