Chapter
3
3-1
Configure the QDC Module's I/O
Your QDC module needs to know the characteristics of your ram (screw)
and clamp sensors. In this chapter, we describe how to determine these
characteristics and download them to the QDC module. Topics include:
signal ranges from pressure and position sensors
minimum and maximum sensor signals corresponding to
minimum and maximum pressures and positions
alarm values and travel limits
We describe how to configure the QDC module in these sections:
select module parameters and I/O ranges
determine initial sensor configuration values
download configuration values to the QDC module
use the set-output operation to move the ram (screw) and clamp
complete your sensor configuration
use optional sensor configurations
Important: You must properly configure the QDC module using
procedures in this chapter before attempting further configurations.
Important: If you have not already done so, install Pro-Set 600 software.
The procedures in this and the next several chapters assume that you have.
You select module parameters and I/O ranges by setting configuration bits
in control words. First, determine and write down correct settings using
Worksheet 3-A through Worksheet 3-C as follows:
To Configure:
In Control Word: Starting At Addr:
Use this Worksheet:
Module Parameters
MCC02
B34/528
Worksheet 3ĆA
Input Range
MCC03
B34/544
Worksheet 3ĆB
Output Range
MCC04
B34/560
Worksheet 3ĆC
Chapter Objectives
Select Module Parameters
and I/O Ranges