MacDon CA25 OM User Manual
Page 28
SECTION 7. OPERATION
169593
26
Revision B
7.2.3.4 Installing
a. Position endshield on endshield support (G),
and locate hole on the stud (H).
b. Secure endshield with acorn nut (F).
c. Close endshield. See Section 7.2.3.2 Closing
(on previous page).
NOTE
Plastic endshields are subject to
expansion or contraction depending
on large temperature variations. Top
pin and lower latch bracket positions
can be adjusted to compensate for
dimensional changes. Refer to next
section.
7.2.3.5 Adjustment
a. Check
gap
‘X’ between the front end of shield
and header frame, and compare to chart below.
TEMPERATURE
Degrees ˚F (˚C)
GAP ‘X’
Inches (mm)
25 (-4)
1-1/8 (28)
45 (7)
1 (24)
65 (18)
13/16 (20)
85 (29)
5/8 (16)
105 (41)
1/2 (12)
125 (52)
5/16 (8)
145 (63)
3/16 (4)
165 (89)
0
(continued next page)
H
G
G
F
X