beautypg.com

MacDon CA25 OM User Manual

Page 177

background image

SECTION 8. MAINTENANCE AND SERVICING

169593

175

Revision B

8.12.8.2 Lexion

500

a. Maintain a 1/8 in. (3 mm) gap between sensor

disc (G) and sensor (H). Adjust by bending
support (J).

b. Replace sensor as follows:

1. Disconnect

connector

(K).

2. Remove screw (L) attaching sensor, and

remove sensor (H).

3. Locate new sensor in support, and secure

with screw (L).

4. Adjust gap between sensor disc (G) and

sensor (H) to 1/8 in. (3 mm) by bending
support (J).

3. Connect to harness at (K).

IMPORTANT

Ensure sensor electrical harness
does NOT contact chain or
sprocket.

8.12.8.3 Lexion

400

a. Maintain a 1/8 in. (3 mm) gap between sensor

disc (G) and sensor (H). Adjust with nuts (J) as
required.

b. Replace sensor as follows:

1. Disconnect

connector

(K).

2. Remove top nut (J), and remove sensor

(H).

3. Remove top nut from new sensor, and

locate in support.

4. Secure with top nut (J).

5. Adjust gap between sensor disc (G) and

sensor (H) to 1/8 in. (3 mm) with nuts (J).

6. Connect to harness at (K).

IMPORTANT

Ensure sensor electrical harness
does NOT contact chain or
sprocket.

K

H

G

J

L

G

H

J

K

This manual is related to the following products: