HP XP Racks User Manual
Page 83
![background image](/manuals/398324/83/background.png)
Table 21 Copy pair statuses of volumes obtained by the YKQRYDEV command (BC Z)
Description
Status of the copy pair in
the storage system
Copy pair status acquired
by YKQRYDEV
SIMPLEX
status.
Simplex
SIMPLEX
PENDING
status (during initial copy).
Pending
PENDING (01)
DUPLEX
status.
Duplex
DUPLEX (02)
Transitioning to the suspend status in normal mode.
Sp-Pend
TRANS (03)
Suspend status.
Split
SUSPOP (04)
Resynchronization is being performed.
Resync
PENDING (05)
SUSPER
status.
Suspend
SUSPER (06)
Transitioning to the suspend status in quick mode.
V-Split
SUSPVS (07)
Resynchronization is being performed.
Resync-R
REVRSY (08)
In transition to Simplex status.
Deleting
TRANS (09)
Using the YKQUERY command to obtain the copy pair status for each copy pair
You can use the YKQUERY or YKEWAIT command or the Copy Group Pair Status panel to obtain
the copy pair status for each copy pair.
The copy pair status for each copy pair is determined by the combination of the copy pair statuses
of the P-VOL and S-VOL. When the status can be obtained from only the P-VOL or S-VOL, the
obtained status will be the copy pair status of the copy pair.
For Continuous Access Synchronous Z, TrueCopy Asynchronous for Mainframe, or Continuous
Access Journal Z, if the command is executed for a remote storage system when a command device
has not been defined, the copy pair status for the remote storage system is not displayed.
CAUTION:
If you attempt to obtain copy pair information from an inaccessible site (due to a line
failure, for example), an error will occur even if information from available sites has been obtained.
You can prevent the error in such cases by executing the YKQUERY command with the TO parameter
specified. This parameter allows you to specify the site (P-VOL or S-VOL when they were defined)
from which information can be obtained. For details about the information that can be obtained
by the YKQUERY command with the TO parameter, in the HP XP7 for Business Continuity Manager
Reference Guide, see the explanation of the REXX variable that is updated by the YKQUERY
command with the TO parameter.
NOTE:
The YKQUERY and YKEWAIT commands determine the copy pair status based on the
collected information, even if the defined copy types or combinations of copy pairs differ from
actual copy types or combinations of copy pairs.
The following common legend is used for
through
show
the correspondence between the P-VOL and S-VOL statuses and the copy pair statuses for each
copy pair.
Legend:
SMP: SIMPLEX
PND: PENDING
DUP: DUPLEX
SOP: SUSPOP
SCU: SUSPCU
SER: SUSPER
Understanding copy group operations
83