HP XP Racks User Manual
Page 34

The following table lists the values of each item. The command to obtain this information was issued
at 10:00:05.
Value description
URG02
URG01
Item
The most recent timestamp
for data received by the
restore journal.
10:00:02
10:00:03
Consistency time (JOURNAL)
The most recent timestamp
for data reflected onto the
S-VOL.
10:00:00
9:59:59
Consistency time (VOLUME)
The difference between the
time when the command
00:00:03
00:00:02
Consistency delta
(JOURNAL)
was issued and the
consistency time (JOURNAL).
The difference between the
time when the command
00:00:05
00:00:06
Consistency delta (VOLUME)
was issued and the
consistency time (VOLUME).
The oldest timestamp for
data that has most recently
10:00:02
EXCTG consistency time
been received by the restore
journals of the consistency
groups (URG01: 10:00:03;
URG02
: 10:00:02) in the
extended consistency group.
The difference between
10:00:05 (the time when the
00:00:03
EXCTG consistency delta
command was issued) and
10:00:02 (the EXCTG
consistency time).
34