Table 9 List of functionalities dependent on the storage system (continued)
Related sections
XP7
XP P9500
XP24000/XP20000
XP12000/XP10000
Function name
No
Yes
Yes
Yes
Select the unit for
differential-data
•
Copy Group
Attributes for
management
(cylinder or track)
Container (CA) panel
3
•
Copy Group
Attributes (CA) panel
3
•
Copy Group
Attributes for
Container (TCA)
panel
3
•
Copy Group
Attributes (TCA) panel
3
Legend:
Yes: Available
No: Not available
1
HP XP P9500 and HP XP7 are the only storage systems for which values other than 00 can be specified for path group
IDs.
2
See the chapter about CLI commands in the HP XP7 for Business Continuity Manager Reference Guide.
3
See the chapter about the ISPF panels in the HP XP7 for Business Continuity Manager Reference Guide.
4
Specification is invalid. For details, see the HP XP P9000 Continuous Access Synchronous for Mainframe Systems User
Guide.
5
See the chapter on data objects in the HP XP7 for Business Continuity Manager Reference Guide.
6
Combination of the Cnt Ac-J Z ATTIME suspend and Delta Resync functions cannot be combined.
7
QUICK mode cannot be specified.
8
See the HP XP7 for Business Continuity Manager Installation Guide
9
4x4x4 configurations are not supported.
The unit (the differential-data management unit) that manages the differential data of a P-VOL and
an S-VOL can be specified in DIF UNIT in the Copy Group Attributes panel (for Cnt Ac-S Z/TCA).
Thus, the units vary for each of the following storage systems that are used:
•
HP XP12000/XP10000 disk array, HP XP24000/XP20000 disk array, or HP XP P9500 disk
array
•
HP XP7 storage
For HP XP7 storage, the unit for differential-data management is track only.
For details about DIF UNIT in the Copy Group Attributes panel (Cnt Ac-S Z/TCA), see the HP XP7
for Business Continuity Manager Reference Guide. For details about the difference management
unit, see the HP XP7 Continuous Access Synchronous for Mainframe User Guide.
Storage system identification
Differences in storage system identification in Business Continuity Manager are described in the
following sections.
Identification on the XP12000/XP10000 disk array
When the storage system is an XP12000/XP10000 disk array, Business Continuity Manager
considers the storage systems themselves to be storage systems and treats the physical DKC serial
numbers assigned to the individual storage systems as the storage systems serial numbers.
shows the storage system serial numbers for XP12000/XP10000 disk arrays.
48