Table 64 Prerequisite Hardware (HyperSwap)
Remarks
Description
Item
TPC-R is necessary at the primary site.
One unit each for the primary and secondary sites.
Host
The configuration indicated on the left
must be used.
Primary site: two XP24000, XP P9500 disk arrays, or
XP7 storage
Storage system
Secondary site: one XP24000, XP P9500 disk array,
or XP7 storage
None
A bidirectional physical path (for logical paths and
delta resync control paths) connected between
Physical path
appropriately configured fibre channel ports is
required between the storage systems of the following
sites:
•
Primary storage system
←→ Local storage system
•
Primary storage system
←→ Remote storage system
•
Local storage system
←→ Remote storage system
Table 65 Storage System Setting Items (HyperSwap)
Remarks
Description
Item
Use Remote Web Console for the setup.
A journal group is required for each storage system.
Journal group
Timer type: SYSTEM
Use Remote Web Console for the setup.
At least one journal volume is required for each
storage system.
Journal volume
Use Business Continuity Manager for
the setup.
Command device
•
For the route in the forward direction (Primary and
local storage system
→ Remote storage system)
•
For the route in the reverse direction (Remote
storage system
→ Primary and local storage
system)
Use Remote Web Console or Business
Continuity Manager for the setup.
Logical path
•
An inter-control unit logical path (bidirectional) must
be established between the primary and local
storage system.
•
An inter-disk controller logical path (bidirectional)
must be established between the primary and
remote storage system.
•
An inter-disk controller logical path (bidirectional)
must be established between the local and remote
storage system.
Use Remote Web Console for the setup.
Add a delta resync control path (bidirectional)
between storage systems.
Delta resync control
path
Preparing the Configuration Files (HyperSwap)
lists the configuration files required for using Business Continuity Manager in
a 2DC configuration with HyperSwap and Continuous Access Journal Z configuration.
216
Configuration definitions