Table 89 Hardware Setting Items (Cnt Ac-J Z ATTIME Suspend)
Remarks
Description
Item
Before performing copy operations, this item must be set
by using the Remote Web Console.
A journal group is required for each of the primary
and secondary sites.
Journal group
Timer type: System
—
At least one journal volume is required for each
journal group.
Journal volume
Before performing copy operations, this item must be set
by using Remote Web Console.
Set this for the secondary site.
BC Z C/T group ID
This item must be set if the Remote DKC Control Function
is to be used.
Command device
•
For the route in the forward direction (Primary
→ Secondary)
This is required when a reverse direction command
device uses the Remote DKC Control Function to operate
a primary site storage system from a secondary site.
•
For the route in the reverse direction (Secondary
→ Primary) (optional)
—
An inter-DKC logical path (bidirectional) must be
established between the primary and secondary
sites.
Logical path
Preparing the software (Cnt Ac-J Z ATTIME Suspend)
lists the software settings for using Business Continuity Manager in the Cnt
Ac-J Z ATTIME suspend function.
Table 90 Software Setting Items (Cnt Ac-J Z ATTIME Suspend)
Remarks
Description
Item
—
Disk configuration definition files are
required at the primary site and secondary
site.
Disk configuration definition
file
This item is not necessary if you use Remote
Web Console to set up logical paths.
An inter-disk controller logical path
(bidirectional) between the primary site and
the secondary site must be defined.
Path set definition files
Set this item before starting a copy
operation.
Forward and reverse direction routes
Route list definition file and
command device definition
file
The forward route is required when you
operate the secondary site storage systems
from the primary site by using the Remote
DKC Control Function. The reverse route is
required when you operate the primary site
storage systems from the secondary site by
using the Remote DKC Control Function.
286 Configuration definitions