Table 20 Copy pair statuses of volumes obtained by the YKQRYDEV command (Cnt Ac-J Z) (continued)
Description
Status of the copy pair in
the storage system
Copy pair status acquired
by YKQRYDEV
The user has suspended the S-VOL. (The P-VOL has been
updated and the differential data between the P-VOL and
S-VOL is being recorded.)
Suspended
SUSPOP (04)
The user has suspended a copy pair for which REVERSE is
specified.
Suspended
SWAPPING (04)
The copy pair has been suspended because the secondary
storage system has received a suspend request from the
primary storage system.
Suspended
SUSPOP (05)
The copy pair has been suspended because the primary
storage system has detected an error status on the secondary
storage system.
Suspended
SUSPCU (06)
The P-VOL has been suspended because the user dissolved
the copy pair from the S-VOL (changed to the SIMPLEX status).
Suspended
SUSPER (07)
The copy pair has been suspended because the primary
storage system detected either an error during migration with
Suspended
SUSPCU (08)
the secondary storage system or an I/O error during update
copying.
The copy pair has been suspended because, when the power
was turned on (IMPL), the primary storage system detected that
Suspended
SUSPER (09)
the pair control information that had been in memory was no
longer available (that is, the information had been lost). This
error occurs when the primary storage system was turned off
for a period that exceeded the backup period for non-volatile
memory.
The copy pair has been suspended because the data between
the P-VOL data and the S-VOL data did not match during the
initial copying phase. Invalid track formatting causes this error.
Suspended
SUSPER (50)
The copy pair is changing to the suspend status.
Suspending
TRANS (60)
The copy pair is changing to the Simplex status.
Deleting
TRANS (61)
The primary storage system has suspended all the copy pairs
due to a planned outage (turned off).
Suspended
SUSPER (62)
Copy pairs are ready to perform a Delta Resync, and a Delta
Resync can be performed.
HOLD
HOLD (70)
A transition to HOLDER status indicates that the differential
data cannot be kept in a journal due to a hardware failure
HOLDER
HOLDER (71)
such as a cache memory, shared memory, or journal volume
failure.
The status of a Delta Resync pair is being changed to the HOLD
status.
HOLDTRNS
HOLDTRNS (72)
The user tried to perform a Delta Resync, but the copy pair
changed to the HOLDER status because the copy pair is not in
HOLDER
HOLDER (73)
a status that allows Delta Resync. In this situation, the
differential data cannot be retained as journal data.
Status when the user performs a Delta Resync, but the
differential data between the journal on the P-VOL of the copy
NODELTA
NODELTA (74)
pair receiving the command and the journal on the S-VOL of
the copy pair receiving the command cannot be properly
applied to the S-VOL. Delta Resyncs cannot be performed in
this status, but a full copy Delta Resync can be performed.
82
Business Continuity Manager with replication products