HP XP Racks User Manual
Page 458
![background image](/manuals/398324/458/background.png)
3.
Restart the monitoring of HyperSwaps by using Business Continuity Manager.
For details, see
“Operation startup procedure” (page 454)
4.
Use TPC-R on the primary host to execute HyperSwap.
The copy direction of Cnt Ac-S copy pairs with the HyperSwap attribute is reversed, and the
groups are moved from the DUPLEX status to the SWAPPING status.
5.
Detect HyperSwaps of the Cnt Ac-S copy pairs with the HyperSwap attribute, and check the
statuses of the copy groups.
•
YKQUERY
6.
On the primary host, execute the YKSUSPND FLUSH command for Cnt Ac-J Z copy pairs
between the local storage system and the remote storage system.
458 Maintenance and troubleshooting operations