beautypg.com

3 raid manager functions on p9500 – HP XP RAID Manager Software User Manual

Page 50

background image

3 RAID Manager functions on P9500

The RAID Manager functions available on the P9500 storage system are more comprehensive than
on previous RAID storage systems.

Command execution using in-band and out-of-band methods

The methods of executing commands provided by RAID Manager can be classified into the in-band
and out-of-band methods.

In-band method. This method transfers a command from the client or the server to the command
device of the storage system via Fibre and executes a RAID Manager operation instruction.

Out-of-band method. This method transfers a command from the client or the server to the
virtual command device in the SVP via LAN, assigning a RAID Manager operation instruction
to the storage system, and executes it.

When executing a command using the in-band and out-of-band methods, a command device or
a virtual command device is set in a configuration definition file as shown in the following figure.

The following figure shows a system configuration example and a setting example of a command
device and a virtual command device using the in-band and out-of-band methods.

Figure 27 System configuration example and setting example of command device and virtual
command device by in-band and out-of-band methods

To set these two methods, a command device or a virtual command device must be set to
HORCM_CMD of a configuration definition file.

50

RAID Manager functions on P9500

This manual is related to the following products: