Table 78 SSB codes returned by raidcom modify snapshot (continued)
raidcom modify snapshot
Description
Error code
Executing/Async
Error message
SSB2
SSB1
The command ends abnormally because the shared memory
(SS3 or more) is not expanded for necessary capacity.
8108
2E21
Executing
CMDRJE
The program product is not installed.
9010
2E21
Executing
CMDRJE
The Fast Snap or Snapshot pair cannot be restored because
the volume that is set the S-VOL Disable is specified as the
P-VOL.
0079
2E30
Executing
CMDRJE
The command ends abnormally because the volume other
than OPEN-V is specified as the P-VOL of a Fast Snap or
Snapshot pair.
007A
2E30
Executing
CMDRJE
The command ends abnormally because the external volume
mapped for the online data migration is specified as the
S-VOL of a Fast Snap or Snapshot pair.
0081
2E30
Executing
CMDRJE
The specified operation is not supported in the current
microcode version.
8000
2E3F
Executing
CMDRJE
An internal error occurred. Call HP Technical Support.
FEEC
2EC6
Executing
CMDRJE
The specified parameter is invalid. Check the HP P9000
RAID Manager Reference Guide.
0002
2EF3
Executing
CMDRJE
Table 79 SSB codes returned by raidcom get snapshot
raidcom get snapshot
Description
Error code
Executing/Async
Error message
SSB2
SSB1
An internal error occurred. Call HP Technical Support.
FEEC
2EC5
Executing
CMDRJE
Table 80 SSB codes returned by raidcom delete snapshot
raidcom delete snapshot
Description
Error code
Executing/Async
Error message
SSB2
SSB1
The value exceeds the range of LDEV number.
0000
2E00
Executing
CMDRJE
The MU number exceeds the maximum.
000B
2E00
Executing
CMDRJE
The command ends abnormally because the volume out of
the range of LDEV number is specified as the P-VOL of a
Fast Snap or Snapshot pair.
0028
2E00
Executing
CMDRJE
The command ends abnormally because the Business Copy
reserved volume is specified as the P-VOL of a Fast Snap
or Snapshot pair.
0033
2E10
Executing
CMDRJE
The command ends abnormally because the Auto LUN
source volume is specified as the P-VOL of a Fast Snap or
Snapshot pair.
0034
2E10
Executing
CMDRJE
The command ends abnormally because the Auto LUN
target volume is specified as the P-VOL of a Fast Snap or
Snapshot pair.
0035
2E10
Executing
CMDRJE
242 Troubleshooting