beautypg.com

HP XP RAID Manager Software User Manual

Page 242

background image

Table 78 SSB codes returned by raidcom modify snapshot (continued)

raidcom modify snapshot

Description

Error code

Executing/Async

Error message

SSB2

SSB1

The command ends abnormally because the shared memory
(SS3 or more) is not expanded for necessary capacity.

8108

2E21

Executing

CMDRJE

The program product is not installed.

9010

2E21

Executing

CMDRJE

The Fast Snap or Snapshot pair cannot be restored because
the volume that is set the S-VOL Disable is specified as the
P-VOL.

0079

2E30

Executing

CMDRJE

The command ends abnormally because the volume other
than OPEN-V is specified as the P-VOL of a Fast Snap or
Snapshot pair.

007A

2E30

Executing

CMDRJE

The command ends abnormally because the external volume
mapped for the online data migration is specified as the
S-VOL of a Fast Snap or Snapshot pair.

0081

2E30

Executing

CMDRJE

The specified operation is not supported in the current
microcode version.

8000

2E3F

Executing

CMDRJE

An internal error occurred. Call HP Technical Support.

FEEC

2EC6

Executing

CMDRJE

The specified parameter is invalid. Check the HP P9000
RAID Manager Reference Guide.

0002

2EF3

Executing

CMDRJE

Table 79 SSB codes returned by raidcom get snapshot

raidcom get snapshot

Description

Error code

Executing/Async

Error message

SSB2

SSB1

An internal error occurred. Call HP Technical Support.

FEEC

2EC5

Executing

CMDRJE

Table 80 SSB codes returned by raidcom delete snapshot

raidcom delete snapshot

Description

Error code

Executing/Async

Error message

SSB2

SSB1

The value exceeds the range of LDEV number.

0000

2E00

Executing

CMDRJE

The MU number exceeds the maximum.

000B

2E00

Executing

CMDRJE

The command ends abnormally because the volume out of
the range of LDEV number is specified as the P-VOL of a
Fast Snap or Snapshot pair.

0028

2E00

Executing

CMDRJE

The command ends abnormally because the Business Copy
reserved volume is specified as the P-VOL of a Fast Snap
or Snapshot pair.

0033

2E10

Executing

CMDRJE

The command ends abnormally because the Auto LUN
source volume is specified as the P-VOL of a Fast Snap or
Snapshot pair.

0034

2E10

Executing

CMDRJE

The command ends abnormally because the Auto LUN
target volume is specified as the P-VOL of a Fast Snap or
Snapshot pair.

0035

2E10

Executing

CMDRJE

242 Troubleshooting

This manual is related to the following products: