Table 77 SSB codes returned by raidcom add snapshot (continued)

raidcom add snapshot

Description

Error code

Executing/Async

Error message

SSB2

SSB1

The command ends abnormally because an unmounted
volume is specified as the S-VOL of a Fast Snap or Snapshot
pair.

000B

2E20

Executing

CMDRJE

The command ends abnormally because the blocked
volume is specified as the S-VOL of a Fast Snap or Snapshot
pair.

000C

2E20

Executing

CMDRJE

The command ends abnormally because the volume in
formatting operation is specified as the S-VOL of a Fast
Snap or Snapshot pair.

000D

2E20

Executing

CMDRJE

The command ends abnormally because the shared
memory (FC, TPF, or Extension1) is not expanded for
necessary capacity.

8107

2E21

Executing

CMDRJE

The command ends abnormally because the shared
memory (SS1 or more) is not expanded for necessary
capacity.

8108

2E21

Executing

CMDRJE

A Fast Snap or Snapshot pair cannot be created due to
one of the following reasons:

8109

2E21

Executing

CMDRJE

The shared memory is not expanded for necessary
capacity.

It is in the initializing process.

The program product is not installed.

9010

2E21

Executing

CMDRJE

A pair cannot be created because the volume is already
used in the S-VOL of a Fast Snap or Snapshot pair is
specified as the P-VOL.

0076

2E30

Executing

CMDRJE

A pair cannot be created because the volume is already
used in the P-VOL of a Fast Snap or Snapshot pair is
specified as the S-VOL.

0077

2E30

Executing

CMDRJE

A pair cannot be created because the volume is already
used in the S-VOL of a Fast Snap or Snapshot pair is
specified as the S-VOL.

0078

2E30

Executing

CMDRJE

The command ends abnormally because the volume other
than OPEN-V is specified as the P-VOL of a Fast Snap or
Snapshot pair.

007A

2E30

Executing

CMDRJE

A pair cannot be created because the volume that is set
the command device is specified as the P-VOL of a Fast
Snap or Snapshot pair.

007B

2E30

Executing

CMDRJE

The command ends abnormally because the volume other
than OPEN-V is specified as the S-VOL of a Fast Snap or
Snapshot pair.

007C

2E30

Executing

CMDRJE

A pair cannot be created because the volume that is set
the command device is specified as the S-VOL of a Fast
Snap or Snapshot pair.

007D

2E30

Executing

CMDRJE

The command ends abnormally because the volume that
has no path definition is specified as the P-VOL of a Fast
Snap or Snapshot pair.

007E

2E30

Executing

CMDRJE