HP XP RAID Manager Software User Manual
Page 195
Table 41 Command error messages (continued)
Value
Recommended action
Condition
Error
message
Error code
247
Verify the device or group name and
add it to the configuration file of the
remote and local hosts.
The designated device or
group name does not exist
in the configuration file.
No such device or
group
EX_ENOENT
246
Verify the device name and add it
to the configuration file of the remote
and local hosts.
The designated device name
does not exist in the
configuration file.
No such device
EX_ENODEV
219
Verify the RAID unit ID and add it to
the configuration file of the remote
and local hosts.
The designated RAID unit ID
does not exist in the
configuration file.
No such RAID unit
EX_ENOUNT
218
Please confirm serial# (Seq#) using
the pairdisplay command, or
The group designated by
Business Copy paircreate
does not have the same
Unmatched Serial#
vs RAID unitID
EX_ENQSER
confirm serial# (Seq#) of the RAID
RAID unit, or the unitID is not storage system using the raidqry
-r
command
identical to the unit ID in the
same RAID serial# (Seq#).
245
Increase the virtual memory capacity
of the system, or close any
Insufficient memory exists.
Not enough core
EX_ENOMEM
unnecessary programs and/or
daemon processes.
131
Confirm the execution right
permission, the extension, and the
execution path of the script file.
The script file specified by
the -zt option cannot be
performed.
Cannot execute
script file
EW_ENESCR
244
Refer to the error message, and
designate an appropriate value.
Tried to use arguments for
an option beyond the
Result too large
EX_ERANGE
maximum allowed, or a
result beyond the maximum
was created.
243
Call HP Technical Support.
Undefined error.
File name too long
EX_ENAMLG
242
Please confirm that the HORC
Manager in the remote host is
A timeout occurred on
remote communication, and
No remote host alive
for remote
EX_ENORMT
running, and then increase the value
HORC Manager failed to
re-execute.
commands or
remote HORCM
of the timeout in the configuration
file.
might be blocked
(sleeping) on an
existing I/O
241
Call HP Technical Support.
Detected a contradiction for
a command.
Invalid RAID
command mode
EX_INVMOD
240
Call HP Technical Support.
Detected a contradiction for
a command.
Invalid RAID
command
EX_INVCMD
239
Verify the device or group name and
add it to the configuration file of the
remote and local hosts.
The designated device or
group name does not exist
in the configuration file, or
No such group
EX_ENOGRP
the network address for
remote communication does
not exist.
238
Call HP Technical Support.
Detected a contradiction for
a command.
Unknown function
code
EX_UNWCOD
237
Refer to the host syslog file, and
investigate the cause of the error.
A read/write to the
command device failed with
an I/O error.
Control command
I/O error
EX_CMDIOE
If the problem persists, collect the
log information of HORCM
Error messages and error codes 195