beautypg.com

HP XP RAID Manager Software User Manual

Page 197

background image

Table 41 Command error messages (continued)

Value

Recommended action

Condition

Error

message

Error code

234

Please issue the pairresync
command manually to the identified

Detected a suspended status
(PSUE) for the paired
volume, before it made it to
the designated status.

Pair suspended at
WAIT state

EX_EWSUSE

failed paired volume to try to recover
it. If the trouble persists, contact HP
Technical Support.

233

Please increase the value of the
timeout using the -t option.

Detected a time out, before
it made it to the designated
status.

Timeout waiting for
specified status

EX_EWSTOT

232

Please confirm that HORC Manager
on the remote host is running.

Timeout error because the
remote did not notify about
expected status in time.

Timeout waiting for
specified status on
the local host

EX_EWSLTO

231

Please confirm the value of “poll” in
the configuration file.

HORC Manager monitoring
was refused.

HORCM Monitor
stopped

EX_ESTMON

230

Please confirm the command name.

An unknown command was
attempted.

Unknown command

EX_UNWCMD

229

Please confirm the pair status using
the pairdisplay command.

The pair status of a volume
within a group is not
identical to the status of the
other volumes in the group.

Inconsistent status in
group

EX_INCSTG

228

Please confirm the pair status using
the pairdisplay command.

The pair status of the target
volume is not appropriate.

Invalid pair status

EX_INVSTP

222

Please confirm the pair status using
the pairdisplay -l command.

The volume status of the
target volume is not
appropriate.

Invalid volume status

EX_INVVOL

220

Please confirm the MU# for the
specified group using the

The MU# of the volume to
be operated is not
appropriate.

Invalid mu# with
HORC or HOMRCF

EX_INVMUN

pairdisplay

command. MU #1/2

cannot be used for Continuous
Access Synchronous, and MU #1/2
must be P-VOL for Business Copy.

227

Please confirm that the Port, Target
ID, LUN are defined correctly under

A device defined in the
configuration file does not

No such LDEV within
the RAID

EX_ENLDEV

HORCM_DEV in the configuration
file.

have a mapping to a real
LUN and target ID within the
RAID storage system.

226

Call HP Technical Support.

Wrong return code.

Invalid return code

EX_INVRCD

225

Check the volume list to see if an
operation was directed to the wrong
S-VOL.

Currency check error for
S-VOL. Cannot guarantee
identical data on S-VOL.

S-VOL currency error

EX_VOLCUR

224

Please confirm the pair status of the
local volume.

The volume specified with
the S-VOL-takeover

Local volume
currency error

EX_VOLCUE

command is not the same as
the P-VOL.

223

Please confirm the pair status of
remote and local volumes using the
pairdisplay

command.

The combination of the
volumes specified with
Swap-takeover is unsuitable.

Local and remote
vol. currency error

EX_VOLCRE

--

Call HP Technical Support.

Wrong error code.

Unknown error
code.

EX_UNWERR

Error messages and error codes

197