beautypg.com

HP XP RAID Manager Software User Manual

Page 232

background image

Table 76 SSB codes that are returned by raidcom add snap_pool command

raidcom add snap_pool

Description

Error code

Executing/
Async

Error message

SSB2

SSB1

The value of LDEV number is out of range.

0000

2E00

Async

Get Command Status

Pool ID is out of range.

6000

2E00

Executing

CMDRJE

The type of pool is invalid.

6001

2E00

Executing

CMDRJE

The maximum reserve ratio for V-VOL is out of range.

6002

2E00

Executing

CMDRJE

The specified LDEV is in the state of blocked.

0009

2E10

Async

Get Command Status

The specified LDEV is in the state of blocked, or not installed.

0011

2E10

Executing

CMDRJE

Fast Snap cannot be used because there are not enough cache
management devices to create pairs.

0050

2E10

Async

Get Command Status

The pool is not in the status where the pool volume can be
added.

6003

2E11

Executing

/Async

CMDRJE

Get Command Status

The operation cannot be done because the power supply is
switched off.

8003

2E11

Async

Get Command Status

The command cannot be accepted. After a while, execute the
same command.

9400

2E11

Executing

CMDRJE

The specified LDEV is not installed.

0000

2E20

Async

Get Command Status

The operation cannot be performed because the memory
capacity of the shared memory (SM) is insufficient.

8103

2E21

Async

Get Command Status

The operation cannot be done because the SM for Fast Snap
or Snapshot is not initialized.

8106

2E21

Async

Get Command Status

Fast Snap or Snapshot program product is not installed.

9007

2E21

Executing

CMDRJE

Exceeded the number of pool volume that can be registered in
a pool.

0005

2E22

Async

Get Command Status

The larger number of drive types than the supported
configuration cannot be added to the specified pool.

000D

2E22

Async

Get Command Status

Pool volume cannot be registered because the drive type of
specified LDEV is different from the other pool volume type, or
the drive type in the pool exceeds the three.

6100

2E22

Async

Get Command Status

The emulation type of specified LDEV cannot be used as a pool
VOL.

0000

2E30

Async

Get Command Status

The specified LDEV has the LU path definition.

0007

2E30

Async

Get Command Status

The specified LDEV is used as a External Storage Access
Manager quorum disk.

000C

2E30

Async

Get Command Status

The specified LDEV is used as a system disk.

000D

2E30

Async

Get Command Status

The specified LDEV is already used as a pool volume.

000E

2E30

Async

Get Command Status

The specified LDEV is a command device.

0010

2E30

Async

Get Command Status

It cannot be used as a pool volume because the size of specified
LDEV is less than 8GB.

0038

2E30

Async

Get Command Status

Creating a pool or adding a pool volume cannot be done
because CLPR is mixed in the specified pool.

0039

2E30

Async

Get Command Status

The specified LDEV is used as a V-VOL.

005C

2E30

Async

Get Command Status

232 Troubleshooting

This manual is related to the following products: