HP XP RAID Manager Software User Manual
Page 251
Table 87 SSB codes that are returned by raidcom delete rcu command (continued)
raidcom delete rcu
Description
Error code
Executing/
Asynchronous
Error message
SSB2
SSB1
The command cannot be accepted. After a while, execute the
same command.
00EE
2ED6
Executing
CMDRJE
An internal error occurred.
3005
2ED6
Asynchronous
Get Command Status
Call HP Technical Support.
The value of SSID on the remote storage system is invalid.
3300
2ED6
Executing
CMDRJE
RCU storage system does not exist.
00D1
2EDE
Executing
CMDRJE
The specified parameter is invalid. Check the HP P9000 RAID
Manager Reference Guide.
3002
2EF3
Executing
CMDRJE
Table 88 SSB codes that are returned by raidcom add rcu command
raidcom add rcu
Description
Error code
Executing/
Asynchronous
Error message
SSB2
SSB1
The value of CU# on the RCU exceeds the effective range.
3001
2E00
Executing
CMDRJE
Invalid product ID or path registration ID.
3005
2E00
Executing
CMDRJE
Command cannot be executed because the parameter of
specified RCU is invalid.
3008
2E00
Asynchronous
Get Command Status
Command cannot be executed because all the CU numbers in
the RCU is not unified at the path that is specified creation or
deletion.
3009
2E00
Asynchronous
Get Command Status
The value of port# on the side of RCU is invalid.
3200
2E00
Executing
CMDRJE
The value of CU number is not enabled.
7100
2E00
Executing
CMDRJE
/Asynchronous
Get Command Status
The value of specified port is invalid.
8400
2E00
Executing
CMDRJE
/Asynchronous
Get Command Status
Failed to establish a path or the deletion operation. The following
factor can be thought.
3101
2E10
Asynchronous
Get Command Status
•
Input parameter is invalid.
•
Port status or the MP Blade status is in the state of abnormal.
•
Cable is not connected correctly.
•
Port is specified incorrectly.
The operation cannot be done because the microcode is being
changed.
8004
2E11
Asynchronous
Get Command Status
The command cannot be accepted. After a while, execute the
same command.
9400
2E11
Executing
CMDRJE
The serial number, the product ID, or the SSID of the target
storage system is incorrect.
3000
2E20
Async
Get Command Status
The specified CU number is not defined, or an LDEV is not
defined under the CU number.
7101
2E21
Asynchronous
Get Command Status
The specified RCU is already registered to another product ID.
3001
2E22
Asynchronous
Get Command Status
Error messages and error codes
251