beautypg.com

HP XP RAID Manager Software User Manual

Page 257

background image

Table 98 SSB codes that are returned by raidcom delete host_grp command

raidcom delete host_grp

Description

Error code

Executing/
Asynchronous

Error message

SSB2

SSB1

The cancelling of the host mode option 61 setting was aborted.

302C

B956

Executing

CMDRJ

The program product is not installed.

304F

B956

Executing

CMDRJE

The value of host group ID exceeds the maximum.

3071

B956

Executing

CMDRJE

The attribute of the specified port is Initiator or External.

3077

B956

Executing

CMDRJE

Deletion cannot be executed because the last path of Business
Copy is included in the host group.

3203

B956

Executing

CMDRJE

Deletion cannot be executed because the last path of Snapshot
is included in the host group.

320A

B956

Executing

CMDRJE

The command device being used at the local RAID Manager
exists under the host group.

3239

B956

Executing

CMDRJE

Table 99 SSB codes that are returned by raidcom add host_grp command

raidcom add host_grp

Description

Error code

Executing/
Asynchronous

Error message

SSB2

SSB1

The program product is not installed.

304F

B956

Executing

CMDRJE

The value of host group ID exceeds the maximum.

3071

B956

Executing

CMDRJE

The attribute of the specified port is Initiator or External.

3077

B956

Executing

CMDRJE

The same host group name is already installed in the specified
port.

3173

B956

Executing

CMDRJE

The default host group name cannot be registered for the host
group ID is other than 0.

3174

B956

Executing

CMDRJE

Table 100 SSB codes that are returned by raidcom modify host_grp command

raidcom modify host_grp

Description

Error code

Executing/
Asynchronous

Error message

SSB2

SSB1

The command device being used at the local RAID Manager
exists under the host group.

0339

B958

Executing

CMDRJE

Changing of the host mode/ host mode option cannot be
executed for the port of Initiator or External.

0350

B958

Executing

CMDRJE

The invalid host mode is specified.

0354

B958

Executing

CMDRJE

The cancelling of the host mode option 61 setting was aborted.

092C

B958

Executing

CMDRJE

The host group ID exceeds the maximum.

0956

B958

Executing

CMDRJE

The program product is not installed.

0957

B958

Executing

CMDRJE

The specified host group is not installed.

0959

B958

Executing

CMDRJE

The command device being used at the local RAID Manager
exists under the host group.

B9F9

B9F9

Executing

CMDRJE

Error messages and error codes 257