beautypg.com

HP XP RAID Manager Software User Manual

Page 235

background image

Table 77 SSB codes returned by raidcom add snapshot (continued)

raidcom add snapshot

Description

Error code

Executing/Async

Error message

SSB2

SSB1

The command ends abnormally because the volumes in
which the number of slots is different are specified as the
P-VOL of a Fast Snap or Snapshot pair and S-VOL.

0031

2E10

Executing

CMDRJE

A pair cannot be created because the Thin Provisioning
V-VOL is specified as the S-VOL of a Fast Snap or Snapshot
pair.

0032

2E10

Executing

CMDRJE

The command ends abnormally because the Business Copy
reserved volume is specified as the P-VOL of a Fast Snap
or Snapshot pair.

0033

2E10

Executing

CMDRJE

The command ends abnormally because the Auto LUN
source volume is specified as the P-VOL of a Fast Snap or
Snapshot pair.

0034

2E10

Executing

CMDRJE

The command ends abnormally because the Auto LUN
target volume is specified as the P-VOL of a Fast Snap or
Snapshot pair.

0035

2E10

Executing

CMDRJE

The command ends abnormally because the Auto LUN
reserved volume is specified as the P-VOL of a Fast Snap
or Snapshot pair.

0036

2E10

Executing

CMDRJE

The command ends abnormally because the P-VOL of a
Business Copy pair is specified as the S-VOL of a Fast Snap
or Snapshot pair.

0037

2E10

Executing

CMDRJE

The command ends abnormally because the S-VOL of a
Business Copy pair is specified as the S-VOL of a Fast Snap
or Snapshot pair.

0038

2E10

Executing

CMDRJE

The command ends abnormally because the Business Copy
reserved volume is specified as the S-VOL of a Fast Snap
or Snapshot pair.

0039

2E10

Executing

CMDRJE

The command ends abnormally because the Auto LUN
source volume is specified as the S-VOL of a Fast Snap or
Snapshot pair.

003A

2E10

Executing

CMDRJE

The command ends abnormally because the Auto LUN
target volume is specified as the S-VOL of a Fast Snap or
Snapshot pair.

003B

2E10

Executing

CMDRJE

The command ends abnormally because the Auto LUN
reserved volume is specified as the S-VOL of a Fast Snap
or Snapshot pair.

003C

2E10

Executing

CMDRJE

A Fast Snap or Snapshot pair cannot be created because
the volume of Continuous Access Journal for the delta

003D

2E10

Executing

CMDRJE

resync is specified as the P-VOL of a Fast Snap or Snapshot
pair.

A Fast Snap or Snapshot pair cannot be created because
the volume of Continuous Access Journal for the delta

003E

2E10

Executing

CMDRJE

resync is specified as the S-VOL of a Fast Snap or Snapshot
pair.

The command ends abnormally because the Quorum disk
is specified as the P-VOL of a Fast Snap or Snapshot pair.

003F

2E10

Executing

CMDRJE

The command ends abnormally because the Quorum disk
is specified as the S-VOL of a Fast Snap or Snapshot pair.

0040

2E10

Executing

CMDRJE

Error messages and error codes 235

This manual is related to the following products: