Table 77 SSB codes returned by raidcom add snapshot (continued)
raidcom add snapshot
Description
Error code
Executing/Async
Error message
SSB2
SSB1
The command ends abnormally because the volumes in
which the number of slots is different are specified as the
P-VOL of a Fast Snap or Snapshot pair and S-VOL.
0031
2E10
Executing
CMDRJE
A pair cannot be created because the Thin Provisioning
V-VOL is specified as the S-VOL of a Fast Snap or Snapshot
pair.
0032
2E10
Executing
CMDRJE
The command ends abnormally because the Business Copy
reserved volume is specified as the P-VOL of a Fast Snap
or Snapshot pair.
0033
2E10
Executing
CMDRJE
The command ends abnormally because the Auto LUN
source volume is specified as the P-VOL of a Fast Snap or
Snapshot pair.
0034
2E10
Executing
CMDRJE
The command ends abnormally because the Auto LUN
target volume is specified as the P-VOL of a Fast Snap or
Snapshot pair.
0035
2E10
Executing
CMDRJE
The command ends abnormally because the Auto LUN
reserved volume is specified as the P-VOL of a Fast Snap
or Snapshot pair.
0036
2E10
Executing
CMDRJE
The command ends abnormally because the P-VOL of a
Business Copy pair is specified as the S-VOL of a Fast Snap
or Snapshot pair.
0037
2E10
Executing
CMDRJE
The command ends abnormally because the S-VOL of a
Business Copy pair is specified as the S-VOL of a Fast Snap
or Snapshot pair.
0038
2E10
Executing
CMDRJE
The command ends abnormally because the Business Copy
reserved volume is specified as the S-VOL of a Fast Snap
or Snapshot pair.
0039
2E10
Executing
CMDRJE
The command ends abnormally because the Auto LUN
source volume is specified as the S-VOL of a Fast Snap or
Snapshot pair.
003A
2E10
Executing
CMDRJE
The command ends abnormally because the Auto LUN
target volume is specified as the S-VOL of a Fast Snap or
Snapshot pair.
003B
2E10
Executing
CMDRJE
The command ends abnormally because the Auto LUN
reserved volume is specified as the S-VOL of a Fast Snap
or Snapshot pair.
003C
2E10
Executing
CMDRJE
A Fast Snap or Snapshot pair cannot be created because
the volume of Continuous Access Journal for the delta
003D
2E10
Executing
CMDRJE
resync is specified as the P-VOL of a Fast Snap or Snapshot
pair.
A Fast Snap or Snapshot pair cannot be created because
the volume of Continuous Access Journal for the delta
003E
2E10
Executing
CMDRJE
resync is specified as the S-VOL of a Fast Snap or Snapshot
pair.
The command ends abnormally because the Quorum disk
is specified as the P-VOL of a Fast Snap or Snapshot pair.
003F
2E10
Executing
CMDRJE
The command ends abnormally because the Quorum disk
is specified as the S-VOL of a Fast Snap or Snapshot pair.
0040
2E10
Executing
CMDRJE
Error messages and error codes 235