HP XP RAID Manager Software User Manual
Page 248
Table 84 SSB codes that are returned by raidcom modify rcu command (continued)
raidcom modify rcu
Description
Error code
Executing/
Async
Error message
SSB2
SSB1
The operation cannot be done because the number of paths
become less than the least path number.
3101
2E23
Executing
CMDRJE
Command cannot be executed because the RCU identification
code of a path is invalid.
3001
2E31
Async
Get Command Status
An internal error occurred.
00EF
2ED6
Executing
CMDRJE
Call HP Technical Support.
The value of SSID for the remote storage system is invalid.
3300
2ED6
Executing
CMDRJE
Table 85 SSB codes that are returned by raidcom delete rcu_path command
raidcom delete rcu_path
Description
Error code
Executing/
Asynchronous
Error message
SSB2
SSB1
The CU# of RCU exceeds the effective value.
3001
2E00
Executing
CMDRJE
The product ID or the path registration ID is invalid.
3005
2E00
Executing
CMDRJE
Command cannot be executed because the parameter of
specified RCU is invalid.
3008
2E00
Asynchronous
Get Command Status
The specified port # on the side of RCU is invalid.
3200
2E00
Executing
CMDRJE
CU number is out of effective range.
7100
2E00
Executing/
Asynchronous
CMDRJE
Get Command Status
The value of specified port is invalid.
8400
2E00
Executing
CMDRJE
/Asynchronous
Get Command Status
Failed to establish a path or the deletion operation. The following
factor can be thought.
3101
2E10
Asynchronous
Get Command Status
•
Input parameter is invalid.
•
Port status or the MP Blade status is in the state of abnormal.
•
Cable is not connected correctly.
•
Port is specified incorrectly.
The operation cannot be done because the microcode is being
changed.
8004
2E11
Asynchronous
Get Command Status
The command cannot be accepted. After a while, execute the
same command.
9400
2E11
Executing
CMDRJE
A logical path cannot be deleted because the specified RCU is
not registered.
3001
2E20
Asynchronous
Get Command Status
The specified CU number is not defined, or an LDEV is not
defined under the CU number.
7101
2E21
Asynchronous
Get Command Status
The operation cannot be done because the number of paths
become less than the least path number.
3101
2E23
Asynchronous
Get Command Status
The port attribute is not Initiator (MCU).
840A
2E30
Executing
CMDRJE
Command cannot be executed because the RCU identification
code of a path is invalid.
3001
2E31
Asynchronous
Get Command Status
248 Troubleshooting