beautypg.com

HP XP RAID Manager Software User Manual

Page 248

background image

Table 84 SSB codes that are returned by raidcom modify rcu command (continued)

raidcom modify rcu

Description

Error code

Executing/
Async

Error message

SSB2

SSB1

The operation cannot be done because the number of paths
become less than the least path number.

3101

2E23

Executing

CMDRJE

Command cannot be executed because the RCU identification
code of a path is invalid.

3001

2E31

Async

Get Command Status

An internal error occurred.

00EF

2ED6

Executing

CMDRJE

Call HP Technical Support.

The value of SSID for the remote storage system is invalid.

3300

2ED6

Executing

CMDRJE

Table 85 SSB codes that are returned by raidcom delete rcu_path command

raidcom delete rcu_path

Description

Error code

Executing/
Asynchronous

Error message

SSB2

SSB1

The CU# of RCU exceeds the effective value.

3001

2E00

Executing

CMDRJE

The product ID or the path registration ID is invalid.

3005

2E00

Executing

CMDRJE

Command cannot be executed because the parameter of
specified RCU is invalid.

3008

2E00

Asynchronous

Get Command Status

The specified port # on the side of RCU is invalid.

3200

2E00

Executing

CMDRJE

CU number is out of effective range.

7100

2E00

Executing/
Asynchronous

CMDRJE

Get Command Status

The value of specified port is invalid.

8400

2E00

Executing

CMDRJE

/Asynchronous

Get Command Status

Failed to establish a path or the deletion operation. The following
factor can be thought.

3101

2E10

Asynchronous

Get Command Status

Input parameter is invalid.

Port status or the MP Blade status is in the state of abnormal.

Cable is not connected correctly.

Port is specified incorrectly.

The operation cannot be done because the microcode is being
changed.

8004

2E11

Asynchronous

Get Command Status

The command cannot be accepted. After a while, execute the
same command.

9400

2E11

Executing

CMDRJE

A logical path cannot be deleted because the specified RCU is
not registered.

3001

2E20

Asynchronous

Get Command Status

The specified CU number is not defined, or an LDEV is not
defined under the CU number.

7101

2E21

Asynchronous

Get Command Status

The operation cannot be done because the number of paths
become less than the least path number.

3101

2E23

Asynchronous

Get Command Status

The port attribute is not Initiator (MCU).

840A

2E30

Executing

CMDRJE

Command cannot be executed because the RCU identification
code of a path is invalid.

3001

2E31

Asynchronous

Get Command Status

248 Troubleshooting

This manual is related to the following products: