beautypg.com

HP XP RAID Manager Software User Manual

Page 237

background image

Table 77 SSB codes returned by raidcom add snapshot (continued)

raidcom add snapshot

Description

Error code

Executing/Async

Error message

SSB2

SSB1

A Fast Snap pair cannot be created because the maximum
number of Snapshot IDs (MU numbers) has already been
in use for the specified P-VOL.

9706

2E10

Executing

CMDRJE

A Fast Snap pair cannot be created because the maximum
number of Snapshot groups has already been defined, or

9707

2E10

Executing

CMDRJE

the maximum number of Fast Snap pairs has already been
defined in the specified Snapshot group.

A Fast Snap pair cannot be created because the DP pool
is being initialized.

9708

2E10

Executing

CMDRJE

An error occurred at the operation of Fast Snap due to one
of the following reasons:

9800

2E10

Executing

CMDRJE

The LDEV number specified for the P-VOL or the S-VOL
is incorrect.

The LDEV specified as the P-VOL or the S-VOL is not
paired.

The pair of the specified P-VOL or the S-VOL is not ready
to perform the specified operation.

The specified Snapshot ID (MU number) is wrong.

The specified Snapshot ID (MU number) is already used.

The specified pool is not in the usable status.

The license capacity has exceeded the maximum.

The control table for Fast Snap is depleted.

A Fast Snap or Snapshot pair cannot be created because
the specified P-VOL is a LUSE volume.

0000

2E13

Executing

CMDRJE

A pair cannot be created because there is a pair in the
specified primary volume, which is using a different pool
number from the specified pool number.

6003

2E13

Executing

CMDRJE

The specified pair operation cannot be performed for the
specified pool.

6004

2E13

Executing

CMDRJE

The consistency group to be used in the specified Snapshot
Group is in one of the following status:

9900

2E13

Executing

CMDRJE

The number of pairs that can be defined in a consistency
group exceeds the maximum.

The pair created by using the same P-VOL already exists
in the specified consistency group.

The specified LDEV is not defined.

0000

2E20

Executing

CMDRJE

The command ends abnormally because an unmounted
volume is specified as the P-VOL of a Fast Snap or Snapshot
pair.

0008

2E20

Executing

CMDRJE

The command ends abnormally because the blocked
volume is specified as the P-VOL of a Fast Snap or Snapshot
pair.

0009

2E20

Executing

CMDRJE

The command ends abnormally because the volume in
formatting operation is specified as the P-VOL of a Fast
Snap or Snapshot pair.

000A

2E20

Executing

CMDRJE

Error messages and error codes 237

This manual is related to the following products: